VIDEO OUT

POWER

: VIDEO IN

: VIDEO OUT

b

Supported coaxial cables

Cable type – Length: 

• RG-59U (3C-2V) – 250 m/273 yd max.
• RG-6U (5C-2V) – 500 m/547 yd max.
• RG-11U (7C-2V) – 600 m/656 yd max.

• When using an RG-59U (3C-2V) cable, do not use it on piping or air 

wiring.

• If you use a cable other than the type above, the image or sync signal will 

be attenuated and will not be transmitted correctly.

b

Attaching the lens

Use any DC type and CS mount lens equipped with an auto iris (sold separately).

3

2

2

1

Brake coil (–)

Brake coil (+)

Drive coil (+)

Drive coil (–)

Pin layout for LENS terminal

• Depending on the type of the lens, the shape of 

the lens plug may differ. In this case, consult your 
dealer or an Authorized Sanyo Service Center.

• Apply adapter ring (sold separately) when you use 

any C mount lens.

5 mm/0.2 in. max.

b

Camera attachment

When attaching the camera, make sure to verify that the attachment surface will allow full 
tightening of the screws. Plaster board, etc., may not give a strong enough attachment, and 
it is recommended to use a reinforcement, or other method so that the screws are anchored 
securely.

b

Flange-back adjustment

This normally does not need adjustment. If the picture is out of focus at the telephoto 
position, adjust the flange-back position as described below.

• When monitoring lighting or other extremely bright objects 

(which exceed the maximum required illumination), 
smearing may occur in the vertical or horizontal direction 
(either above and below the high-brightness object or as a 
perpendicular band). In such a case, adjust the angle of 
illumination and other factors while observing the monitor.

• You can change the bracket topside down. Make sure to 

use the longer screws 

A

 to secure the bracket.

B

 Camera screws (shorter)

A

 Bracket screws (longer)

A

B

Repeat steps 

2

 and 

3

 until the image stays in-focus when changing from a wide-angle position to 

a telephoto position.

3

2

Set to the maximum telephoto 
position and focus the picture.

Set to the maximum 
wide-angle position 
and focus the 
picture.

1
4

Loosen.

Tighten.

LOCK

b

Power cable

<AC 24 V connection>

<DC 12 V connection>

To prevent a fire hazard use any UL 
listed wire rated VW-1.

Check that polarity is correct.

GND AC24V

DC12V

GND AC24V

DC12V

b

Camera adjustments/settings

The camera comes pre-adjusted and ready to install at the 
time of factory shipment, but you can make adjustments or 
settings if you need.

If you have trouble adjusting the camera, consult your dealer 
or an Authorized Sanyo Service Center.

1

Iris setting (EI/AI)

NOTE on EI setting:

• Set the lens aperture to the shortest F stop.

• If fluorescent lighting is used where the camera is installed, the 

object will flicker as a result. This type of phenomenon can be 
avoided by replacing the fluorescent lighting with incandescent 
lamps.

• If the light entering the lens exceeds the maximum required 

illumination, the image cannot be displayed properly. In that 
case, manually adjust the lens iris.

NOTE on AI setting:

If the entire image is too dark or too bright, adjust the contrast 
using the LEVEL dial.

L

(Counterclockwise):
Closes the lens iris, making the entire image darker.

H

(Clockwise): 
Opens the lens iris, making the entire image brighter.

2

Day/Night function (D/N)

3

Backlight compensation 
(BLC)

Only when using an auto-iris lens

* If the background of the object is extremely dark, set to Center zone 

metering.

4

White balance (WB)

5

Sync setting (LL/INT)

* Adjust the roll by turning the PHASE dial on the second and subsequent 

cameras.

EI

D/N

CENT

ON

MANU

LL

AI

OFF

MULTI

INT

WB

ATW

BLC

OFF

PHASE

LEVEL

R

B

L

H

EI (Electronic Iris)

When using a manual or fixed 
iris lens and the electronic iris 
function is on

• For indoor use

AI (Auto Iris)

When using an auto-iris lens

ON

Automatically switches to 
B/W (non-IR sensitive) to 
optimize low light surveillance

OFF

Color images only

1

1

LEVEL

L

H

B/W

Color

B/W

Color

Switchover point

2

2

MULTI 
(Multi-spot metering)

Backlight compensation 
to the entire screen*

CENT
(Center zone metering)

Backlight compensation 
to the central portion of 
the screen

OFF

High

Normal

MANU
(Manual white balance)

ATW 
(Auto-Tracing 
White balance)

LL (Line-Lock)

(Only when using an AC power supply)
Synchronizes the unit with power 
frequency*

INT 
(Internal sync)

If the vertical roll cannot be corrected by adjusting the 
PHASE dial on the second and subsequent cameras, try 
adjusting the PHASE dial on the first camera. If it still cannot 
be corrected, please check that the polarity of the power 
cords of all connected devices is correct.

4

3

4

3

4

3

4

3

Turn clockwise to 
augment the color.

WB

R

B

5

5

6

PHASE

6

CONNECTIONS AND ADJUSTMENTS