background image

SETTINGS

B: White balance adjustment

Normally the 

WB

 (white balance) switch is

set to the 

A

 (automatic) position and the

white balance is adjusted automatically. If a
manual white balance adjustment is
necessary, follow the steps below.
Set the 

WB

 switch to the 

M

 (manual)

position, then adjust the colour.

Turn 

R

 (VR403) to set the red ratio

and/or 

B

 (VR402) to set the blue ratio.

C: Electronic iris function setting

Use a manual iris lens and set the 

EI/BLC

switch to the 

EI

 (electronic iris)

-ON

position, to engage the electronic iris
function.
Open the lens iris (shortest F stop setting).
The dynamic range of the electronic iris will
be as indicated in table 

A

.

CAUTION:

The electronic iris is suitable for normal
indoor use. When the 

EI/BLC

 switch is

set to the 

EI-ON

 position, do not use an

auto-iris lens.

If used under fluorescent light, the
image may flicker. In such a case,
change to incandescent lighting or set
the 

EI/BLC

 switch to the 

OFF

 position

and use an auto-iris lens.

When shooting bright subjects, pay
attention to the light angle in order to
avoid or minimize the smear
phenomenon effect.

Table A

F stops

Minimum

illumination

Maximum

illumination

F 1.2

1.4 lux

70,000 lux

F 1.4

1.9 lux

95,000 lux

When using an auto-iris lens (for
indoor/outdoor use)

Set the 

EI/BLC

 switch to the 

OFF

 position.

CAUTION:

If conditions are outside the electronic iris
operation range or more than the
maximum illumination, it will cause
saturation of the CCD. In that case, use a
manual iris lens.

D:Backlight compensation setting

Use an auto-iris lens and set the 

EI/BLC

switch to the 

BLC

 (backlight compensation)

-

ON

 position, to engage the backlight

compensation function.
A clear picture can be obtained, with the
multi-zone light measuring system.
(See page 

3

.)

VR403 VR402

W

B

A

M

ON

OFF

ON

EI

BLC

ON

OFF

ON

EI

BLC

L53L4/XE  GB  1995, 8, 28

English

 11

Summary of Contents for VCC-3924P

Page 1: ...INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D INSTRUCTIONS COLOUR CCD camera CCD Farbkamera Caméra CCD COULEUR VCC 3924P ...

Page 2: ...wing settings and adjustments If you need help with installation and or settings please consult your dealer Auto iris lens setting 6 7 Line phase adjustment 10 White balance adjustment 11 Electronic iris function setting 11 Backlight compensation setting 11 Lens iris adjustment 12 Flange backadjustment 12 CAUTION Before installing and using the camera please read this manual carefully Be sure to k...

Page 3: ...ptor 5 mm 1 pc The C mount adaptor must be used to be able to install a C mount lens on the camera 2 Lens iris plug 4 pin 1 pc 1 2 This apparatus complies with EC Directives 89 336 EEC 92 31 EEC and 93 68 EEC ENGLISH 2 English ...

Page 4: ...lustrated below Then the iris is automatically set so the outside zone B brightness is given less weight than the brightness from the centre zone A giving the best possible image 1 3 inch solid state image device CCD CS type lens mount C mount lenses can also be used with the supplied C mount adaptor Terminology explanation About the DC type lenses These lenses use a DC power supply without amplif...

Page 5: ... transformer audio speakers the magnetic field they generate will distort the image Protect from humidity and dust To prevent damages to the camera do not install it where there is greasy smoke or steam where the dampness may get too high or where there is a lot of dust Protect from high temperatures Do not install close to stoves or other heat generating devices such as spotlights etc or where it...

Page 6: ...e page 7 B Installation bracket The bracket can be fitted at the top or bottom of the camera To fix the bracket make sure to use the screws that held the bracket before and use the other two screws to seal the openings on the opposite side 1 Opening sealing screws M3x4 shorter 2 Bracket fixing screws M3x6 longer 3 Threaded hole for the support 1 4 20 UNC Mounting at the top R1 Mounting at the bott...

Page 7: ...e lens plug to the LENS connector on the side of the camera When using lenses from other makers make sure that the pins connections in the plug correspond to the ones of the camera Refer to the lens specifications to check the pins connections in the plug If they are different than indicated below remove the original plug and connect the supplied plug according to the diagram below For VIDEO type ...

Page 8: ...layout are different the supplied lens iris plug will have to be fitted in order to be able to connect the lens to the LENS connector on the side of the camera LENS connector layout 1 12 V DC 50 mA max 2 Not used 3 Video output 1 0 Vp p high impedance 4 Ground for video signal and DC power 5 Set the A I LENS switch to the VIDEO position Set the ALC and LEVEL controls on the lens to adjust the iris...

Page 9: ... to use a cable with an earth line 22AWG or more to connect to the earth connector 3 Turn on the power of all the devices connected to the camera When the power is connected to the camera the POWER indicator A will light Adjust the picture on the monitor using the Brightness and Contrast controls Coaxial cable type and maximum length Cable type RG 59U 100 m maximum Cable type RG 39U 200 m maximum ...

Page 10: ...d for each camera The peripheral devices VCR monitor etc and cables are sold separately A Connection using a quad compressor B Connection using a camera switcher Refer to page 10 for line phase settings CAUTION Before connecting and using the other devices please read carefully the corresponding instruction manual A Video signal connections VIDEO IN VIDEO OUT CAMERA IN B English 9 ...

Page 11: ...amera 1 If it still cannot be corrected please check that the polarity of the power cords of all connected devices is correct The vertical roll can also be adjusted using an oscilloscope 1 Set the SYNC switch to the L L position 2 Connect the video signal for camera 1 and camera 2 output from the camera switcher to the oscilloscope 3 Using the LINE PHASE volume on both cameras adjust to eliminate ...

Page 12: ...ed under fluorescent light the image may flicker In such a case change to incandescent lighting or set the EI BLC switch to the OFF position and use an auto iris lens When shooting bright subjects pay attention to the light angle in order to avoid or minimize the smear phenomenon effect Table A F stops Minimum illumination Maximum illumination F 1 2 1 4 lux 70 000 lux F 1 4 1 9 lux 95 000 lux When...

Page 13: ...kground is extremely bright or dark If the brightness of the picture on the monitor is not correct F Flange back adjustment If the pick up surface is not correctly positioned with relation to the lens focal point the picture will be out of focus in particular when using auto iris power zoom lenses sold separately If that is the case adjust the flange back position as described below 1 Using a scre...

Page 14: ...ng a DC type lens the LEVEL volume inside the camera casing should be adjusted B When using a VIDEO type lens the LEVEL volume on the lens should be adjusted The picture is not clear Is the monitor correctly adjusted Is the flange back position correctly set Is the lens focus correctly adjusted Are the lens surfaces clean If there is dust or finger prints on the lens the image quality will deterio...

Page 15: ...ux with a F 1 4 lens Backlight compensation Manual ON OFF switching multi zone light measuring system Electronic iris function Manual ON OFF switching Flange back 12 5 mm 0 5 mm White balance Automatic TTL system Manual Gain control Automatic Gamma correction γ 0 45 Lens mount CS mount or C mount with the supplied adaptor Environmental conditions Temperature 10 C 50 C Humidity less than 90 no cond...

Reviews: