SETTINGS
B: White balance adjustment
Normally the
WB
(white balance) switch is
set to the
A
(automatic) position and the
white balance is adjusted automatically. If a
manual white balance adjustment is
necessary, follow the steps below.
Set the
WB
switch to the
M
(manual)
position, then adjust the colour.
•
Turn
R
(VR403) to set the red ratio
and/or
B
(VR402) to set the blue ratio.
C: Electronic iris function setting
Use a manual iris lens and set the
EI/BLC
switch to the
EI
(electronic iris)
-ON
position, to engage the electronic iris
function.
Open the lens iris (shortest F stop setting).
The dynamic range of the electronic iris will
be as indicated in table
A
.
CAUTION:
•
The electronic iris is suitable for normal
indoor use. When the
EI/BLC
switch is
set to the
EI-ON
position, do not use an
auto-iris lens.
•
If used under fluorescent light, the
image may flicker. In such a case,
change to incandescent lighting or set
the
EI/BLC
switch to the
OFF
position
and use an auto-iris lens.
•
When shooting bright subjects, pay
attention to the light angle in order to
avoid or minimize the smear
phenomenon effect.
Table A
F stops
Minimum
illumination
Maximum
illumination
F 1.2
1.4 lux
70,000 lux
F 1.4
1.9 lux
95,000 lux
When using an auto-iris lens (for
indoor/outdoor use)
Set the
EI/BLC
switch to the
OFF
position.
CAUTION:
If conditions are outside the electronic iris
operation range or more than the
maximum illumination, it will cause
saturation of the CCD. In that case, use a
manual iris lens.
D:Backlight compensation setting
Use an auto-iris lens and set the
EI/BLC
switch to the
BLC
(backlight compensation)
-
ON
position, to engage the backlight
compensation function.
A clear picture can be obtained, with the
multi-zone light measuring system.
(See page
3
.)
VR403 VR402
W
B
A
M
ON
OFF
ON
EI
BLC
ON
OFF
ON
EI
BLC
L53L4/XE GB 1995, 8, 28
English
11