– 17 –
Note:
Do not vibrate during the adjustment.
If readjusting after it has already been adjusted, wait for 15
minutes or more for the unit to cool down first.
Adjustment method:
1. Set the camera so that it becomes center of the siemens
star chart in the collimator (zoom wide and tele).
(Set a distance of 0.5-1.0 cm between camera lens and
collimator lens. Do not touch the each lens.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Select “Infinity Cal.” on the LCD “Test”, and click the “Yes”.
5. Lens infinity adjustment value will appear on the screen.
6. Click the OK.
3-8. Adjust Specifications
1. Lens Adjustment (Infinity)
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP1
Factory
Cord
Setting
Language
Setting
COMPL PWB VF1
COMPL PWB ST1
COMPL PWB ST2
Reset
Setting
LENS
Lens
Adjust-
ment
(1 m)
AWB
Adjust-
ment
USB
storage
information
registration
CMOS
White Point
Defect
Detect
Adjustment
CMOS Black
Point And
White Point
Defect Detect
Adjustment
In Lighted
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
COMPL PWB TB1
ASSY, FLEXIBLE PWB CA1
Lens
Adjust-
ment
(Infinity)
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
Refer to
3-13. Firmware uploading procedure. (Page 21)
Camera
Collimator
Gyro
Sensor
Zero
Offset
Adjustment