6. ELECTRICAL DATA
6-1. Electrical Characteristics
Model
STB0810C1
Model
STB1010C1
Model
STB1020C1
Model
STB1220C1
Outdoor Unit
Complete Unit
Fan Motor
Compressor
Performance at
230 / 208V 1-phase 60Hz
Rating Conditions
Running Amps.
A
0.61
/
0.64
5.49
/
5.96
6.1
/
6.6
Power Input
kW 0.142 / 0.132
1.208 / 1.198
1.35
/
1.33
Full Load Conditions Running Amps.
A
0.61
/
0.64
6.29
/
6.96
6.9
/
7.6
Power Input
kW 0.142 / 0.132
1.428 / 1.438
1.57
/
1.57
Rating Conditions
: Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 90°F (32.2°C) D.B. / 73°F (22.8°C) W.B.
Outdoor Air Temperature 110°F (43.3°C) D.B.
Outdoor Unit
Complete Unit
Fan Motor
Compressor
Performance at
230 / 208V 1-phase 60Hz
Rating Conditions
Running Amps.
A
0.61
/
0.64
4.39
/
4.66
5.0
/
5.3
Power Input
kW 0.142 / 0.132
0.998 / 0.978
1.14
/
1.11
Full Load Conditions Running Amps.
A
0.61
/
0.64
4.99
/
5.26
5.6
/
5.9
Power Input
kW 0.142 / 0.132
1.118 / 1.098
1.26
/
1.23
Outdoor Unit
Complete Unit
Fan Motor
Compressor
Performance at
115V 1-phase 60Hz
Rating Conditions
Running Amps.
A
1.26
9.34
10.6
Power Input
kW
0.145
1.055
1.20
Full Load Conditions Running Amps.
A
1.26
11.04
12.3
Power Input
kW
0.145
1.255
1.40
Outdoor Unit
Complete Unit
Fan Motor
Compressor
Performance at
115V 1-phase 60Hz
Rating Conditions
Running Amps.
A
1.26
7.04
8.3
Power Input
kW
0.145
0.795
0.94
Full Load Conditions Running Amps.
A
1.26
8.34
9.6
Power Input
kW
0.145
0.935
1.08
Cooling only models
18