SAP-CMRV3146EH
SAP-KMRV96EH
×
4
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
1. The values shown in perfromance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Table" in this manual.
Indoor Unit: SAP-KMRV96EH 4units
Outdoor Unit: SAP-CMRV3146EH 1unit
2. Rating conditions are: Cooling: Indoor air temp. 27°C D.B. / 19°C W.B.
Outdoor air temp. 35°C D.B. / 24°C W.B.
Heating: Indoor air temp. 20°C D.B.
Outdoor air temp. 7°C D.B. / 6°C W.B.
Hi
Refrigerant Control
( 3.4 to 9.8 )
( 11,600 to 33,400 )
7.58
1,725
8.96
2,040
8.0
27,200
9.4
32,000
( 2.9 to 9.2 )
( 9,900 to 31,400 )
Shipping Volume
Cooling
Heating
3,030
Cooling
Heating
Net
Shipping
Weight
Height
×
Width
×
Depth
kg
kg
m
3
mm
230V
3,030
198 to 264
Dimensions & Weight (Outdoor Unit)
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Air Circulation (High)
W
Power Input
V
A
Available Voltage Range
Running Amperes
Narrow tube
Wide tube
Refrigerant
mm (in.)
Tube Diameter
mm (in.)
82.0
86.0
0.45
890
×
900
×
320
6.35 (1/4")
×
4
9.52 (3/8")
×
2 + 12.7 (1/2")
×
2
m
Flare Type
30
Electric Expansion Valve
Compressor
Refrigerant / Amount charged at shipment
kg
DC Twin Rotary (Inverter)
R410A / 3.8
Controls
Fan Speeds
Microprocessor
Auto (Hi, Me, Lo)
Features (Outdoor Unit)
C.O.P.
Compressor Locked Rotor Amperes
W/W
kW
Performance
-
4.61
48
50
%
Power Factor
99
99
A
17.0
Type
Voltage Rating
BTU/h
Capacity
m
3
/h
4-Room Multi Outdoor Unit
E.E.R.
W/W
4.64
-
Number of Connectable Indoor Units
4
Number of Operatable Indoor Units
4
Max. Capacity of Operating Indoor Units
kW
14.7
Power Source
220 to 240V Single-Phase 50Hz
Height
×
Width
×
Depth
mm
Package Dimensions
1,019
×
1,050
×
423
Operation Sound
dB-A
Max. allowable tubing length per unit
Outdoor Unit
Indoor Unit
11