4. COOLING CAPACITY
■
1 - indoor unit in operation A(or B)
Indoor Unit
SAP – K97AHA (
✕
1)
Outdoor Unit
SAP – CM1827AHA
240 V Single phase 50 Hz
g
RATING CAPACITY
2.65 kW
EVAPORATOR
CONDENSER
ENT. TEMP. °C
OUTDOOR AMBIENT TEMP. °C
W.B.
D.B.
20
25
30
35
40
43
TC
2.67
2.55
2.44
2.32
2.18
2.01
CM
0.69
0.75
0.80
0.86
0.98
1.10
21
SHC
1.81
1.75
1.70
1.64
1.57
1.49
15
23
SHC
2.04
1.98
1.92
1.86
1.79
1.71
25
SHC
2.26
2.20
2.14
2.09
2.02
1.93
27
SHC
2.48
2.43
2.37
2.31
2.18
2.01
29
SHC
2.67
2.55
2.44
2.32
2.18
2.01
31
SHC
2.67
2.55
2.44
2.32
2.18
2.01
TC
2.86
2.74
2.62
2.49
2.34
2.15
CM
0.71
0.77
0.83
0.89
1.01
1.13
21
SHC
1.59
1.53
1.47
1.41
1.34
1.26
17
23
SHC
1.81
1.75
1.69
1.63
1.56
1.48
25
SHC
2.03
1.97
1.91
1.86
1.79
1.70
27
SHC
2.26
2.20
2.14
2.08
2.01
1.93
29
SHC
2.48
2.42
2.36
2.30
2.23
2.15
31
SHC
2.70
2.64
2.58
2.49
2.34
2.15
TC
3.05
2.92
2.78
# 2.65
2.49
2.29
CM
0.73
0.79
0.85
0.91
1.03
1.16
21
SHC
1.34
1.28
1.23
1.17
1.10
1.02
19
23
SHC
1.57
1.51
1.45
1.39
1.32
1.24
25
SHC
1.79
1.73
1.67
1.62
1.55
1.47
27
SHC
2.01
1.96
1.90
1.84
1.77
1.69
29
SHC
2.24
2.18
2.12
2.06
2.00
1.91
31
SHC
2.46
2.40
2.34
2.29
2.22
2.14
TC
3.23
3.09
2.95
2.81
2.64
2.43
CM
0.76
0.82
0.87
0.94
1.06
1.19
23
SHC
1.32
1.26
1.21
1.15
1.08
1.00
21
25
SHC
1.55
1.49
1.43
1.37
1.31
1.23
27
SHC
1.77
1.71
1.65
1.60
1.53
1.45
29
SHC
1.99
1.93
1.88
1.82
1.75
1.67
31
SHC
2.22
2.16
2.10
2.04
1.98
1.90
TC
3.43
3.28
3.12
2.95
2.76
2.57
CM
0.77
0.84
0.90
0.96
1.09
1.21
23
25
SHC
1.29
1.23
1.17
1.11
1.04
0.97
27
SHC
1.51
1.45
1.40
1.33
1.26
1.20
29
SHC
1.74
1.68
1.62
1.56
1.49
1.42
31
SHC
1.96
1.90
1.84
1.78
1.71
1.64
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM :
Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
8
NOTE
A : SAP–K97AHA
B : SAP–K97AHA
Summary of Contents for SAP-CM1821AHA