![background image](http://html.mh-extra.com/html/sanyo/sap-c181a/sap-c181a_technical-and-service-manual_363682008.webp)
4
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit
SAP – K181A
Controller PCB
Part No.
POW-K181GJ
Controls
Microprocessor
Control circuit fuse
250 V 3.15 A
Remote Control Unit
RCS-7S3E
Fan & Fan Motor
Type
Cross-flow
Q'ty ... Dia. and length
mm
1 ... ø88 / L746
Fan motor model ... Q'ty
UF2-31A5P-S ... 1
No. of poles ... rpm (240 V, High)
2 ... 1,440
Nominal output
W
30
Coil resistance (Ambient temp. 20°C)
Ω
WHT-BRN : 133.7
WHT-PNK : 168.4
— —
— —
— —
Safety devices
Type
Internal protector
Operating temp.
Open
°C
130±8
Close
Automatic reclosing
Run capacitor
µF
2.0
VAC
440
Flap Motor
Type
Stepping motor
Model
MP24GA2
Rating
DC 12 V
Coil resistance (Ambient temp. 25°C)
Ω
Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%
Heat Exch. Coil
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.3
Face area
m
2
0.156
DATA SUBJECT TO CHANGE WITHOUT NOTICE.