-184-
Status read command
The command is sent from PC to the projector with the
format below;
'CR' [Command] 'CR'
Command: one character (refer to the command table
below.
The projector decodes the command and returns the
'Character string' with the format below;
Format
command
Function
Projector
return
Projector status
CR0
Status Read
00
Power On
80
Stand-by mode
40
Countdown
0
Cooling down
10
Power Malfunction
8
Cooling down at the temperature anomaly
0
Unable to receive the RC3C command.
4
Cooling down at Power Management mode
04
Power Management mode after Cooling down
1
Cooling down after the projector is turned off when the lamps
are out.
81
Stand-by mode after Cooling down when the lamps are out.
88
Stand-by mode after Cooling down at the temperature
anomaly.
C
Cooling down when the projector is turned off by the shutter
management function.
8C
Stand-by mode after Cooling down by the shutter management
function.
CR6
Temperature Read
S1 S
S1 = Temperature at Sensor 1 (˚C)(Temp A)
S = Temperature at Sensor (˚C)(Temp C)
(ex.) S1 = 1.3˚C, S = 3.4˚C
--> The projector displays “1.3 3.4 ”
( For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
?
Communication failure
The tables show the typical command lists for controlling the projector. Please consult your local dealer for further
information of other commands.
Serial Control
Summary of Contents for QuaDrive PLC-HF15000L
Page 190: ... 190 IC Block Diagrams FA5501 PFC IC1601 IC1651 HIN202 RS232C Driver IC3801 ...
Page 192: ... 192 IC Block Diagrams M62393 DAC IC7802 IC5691 IC5692 PIC17F67 Network IC8301 ...
Page 193: ... 193 IC Block Diagrams TE7783 I O Expander IC1801 ...