background image

When the Projector is turned on, the POWER indicator lights in green. 
* When the POWER indicator does not light and the WARNING FILTER indicator flashes, the filter is not

attached to the Smoke Resistant Box. In this case, the READY indicator on the Projector does not light
and the Projector can not be turned on.

INDICATORS OPERATION

WARNING FILTER . . . . Normally this does not light. Should the filter become clogged with dust particles

indicator flashes orenge. When the filter needs to be replaced, indicator lights in
orange. The filter should then be replaced immediately. When the filter is not
attached, the indicator will flash.

WARNING . . . . . . . . . . Normally this does not light. When the box's fan is operating abnormally, indicator

flashes red. When this occurs, turn off power immediately and request a
maintenance check. Do not leave the Smoke Resistant Box operational while the
indicator is flashing as it may become a fire and/or accident hazard.

When the Smoke Resistant Box is used for the first time, the initial set-up should be performed in the
following procedures. The Smoke Resistant Box cannot be operated or handled properly without this initial
set-up.

First, properly attach the Smoke Resistant Box to
the Projector.

Turn on the Projector and display some images.
Check that each indicator on the Smoke Resistant
Box lights normally.

Go to next page

7

OPERATION

1

2

OPERATION

INDICATORS

ORANGE

RED

GREEN

OFF

OFF

ON

INITIAL SET-UP BEFORE USE

INITIAL SET-UP BEFORE USE

INITIAL SET-UP BEFORE USE

Summary of Contents for POA-SR-140

Page 1: ...MODEL POA SR 140 Smoke Resistant Box Owner s Manual ...

Page 2: ...IS UNIT THIS SYMBOL INDICATES THAT THERE ARE IMPORTANT OPERATING AND MAIN TENANCE INSTRUCTIONS IN THE OWN ER S MANUAL WITH THIS UNIT Federal Communication Commission Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the e...

Page 3: ... two powerful silent rotary fans and cool down the Projector efficiently It has been designed for easy mounting 3 FEATURES FEATURES FEATURES 3 PART NAMES 4 INSTALLATION 5 OPERATION 7 FILTER REPLACEMENT 8 FILTER TIME CHECK AND RESET 10 APPENDIX 11 MAINTENANCE 11 TROUBLESHOOTING 11 DIMENSIONS SPECIFICATIONS TABLE OF CONTENTS ...

Page 4: ...4 PART NAMES PART NAMES MOUNTING SCREWS provided on each corner Screws are provided in the holes INDICATORS CONNECTOR FILTER FILTER COVER AIR INTAKE VENTS REAR FRONT ...

Page 5: ...S If the Air Intake is covered there will be in sufficient cooling which may result in failure or fire CAUTION UNPLUG THE PROJECTOR FROM THE AC OUTLET WHEN INSTALLING THE SMOKE RESISTANT BOX ATTACHING THE SMOKE RESISTANT BOX WHILE THE PROJECTOR IS CONNECTED TO ELECTRICITY MAY DAMAGETHE BOX OR CAUSE ITTO MALFUNCTION AIR INTAKE VENTS At least 20 50cm 30 75cm At least At least 40 100cm FRONT PROCEDUR...

Page 6: ...and use a Phillips head screwdriver to tighten the four fixed screws to fix the box in place Check that the Smoke Resistant Box is fixed in place with the four screws and no wide gap exists between the projector body and the box 6 INSTALLATION 3 4 5 6 CAUTION TAKE CARE NOT TO TOUCH THE CONNECTOR OR APPLY SHOCK THAT MAY DAMAGE THE CONNECTOR PINS PHILLIPS HEAD SCREWDRIVER THERE SHOULD BE NO WIDE GAP...

Page 7: ...his does not light When the box s fan is operating abnormally indicator flashes red When this occurs turn off power immediately and request a maintenance check Do not leave the Smoke Resistant Box operational while the indicator is flashing as it may become a fire and or accident hazard When the Smoke Resistant Box is used for the first time the initial set up should be performed in the following ...

Page 8: ...menu When replacing the filter replace with a specified filter A replacement filter can be ordered through your dealer When ordering the filter give the following information to the dealer Replacement Filter type No POA FIL 140 Smoke Resistant Box type No POA SR 140 Press the PUSH button on the filter cover 8 OPERATION FILTER REPLACEMENT 3 4 PUSH BUTTON CAUTION WHEN REPLACINGTHE FILTER TURN OFFTHE...

Page 9: ...e filter time Refer to FILTER TIME CHECK AND RESET 9 OPERATION 2 3 4 5 FILTER COVER USED FILTER CAUTION USE ONLY REPLACEMENT FILTERS RECOMMENDED BY THE MANUFACTURER THE USE OF OTHER FILTERS MAY CAUSE THE BOX TO MALFUNCTION OR ACCIDENT MAY RESULT CAUTION TAKE CARE NOT TO DAMA GE THE FILTER DETECTION SWITCH LOCATED INSIDE THE BOX WHEN IN SERTINGTHE FILTER NEW FILTER FILTER DETECTION SWITCH ...

Page 10: ...eset other than filter change Check that the Smoke Resistant Box is properly attached to the projector Turn on the projector and display the screen Check all indicators on the Smoke Resistant Box light normally Select SPECIAL in the projector s menu Then select Filter Select Option box and then select Reset and then Yes A message Please wait will appear When it disappears Filter Time reset is comp...

Page 11: ...hen using a chemical cloth please follow the instructions carefully CLEANING AIR INTAKE VENTS When using under dusty or smoky conditions the performance may be impaired Remove dust frequently using a vacuum cleaner etc 11 APPENDIX MAINTENANCE TROUBLESHOOTING PROBLEM PROBLEM TRY THESE SOLUTIONS TRY THESE SOLUTIONS PROBLEM TRY THESE SOLUTIONS NO POWER Check that the Projector is connected to a power...

Page 12: ...e proof and dustproof box DIMENSIONS 6 5 x8 5 x18 1 165mm x 216mm x 461mm NET WEIGHT Approximately 7 5lbs 3 4Kg AIR CAPACITY Approximately 2 0m min 3 INDICATORS POWER WARNING FILTER WARNING OPERATING CONDITIONS 41 to 95 5 to 35 indoors Owner s Manual Smoke Resistant Box 1 NAME NAME QUANTITY QUANTITY CONTENTS CONTENTS NAME QUANTITY CONTENTS SANYO Electric Co Ltd Printed in Japan ...

Reviews: