-24-
Electrical Adjustments
1. Receive the 16-step gray scale computer signal with
Input 1 [COMPUTER]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+) and
chassis ground (-).
4. Select group no. “
500
”, item no. “
0
” and change data
value to adjust the pedestal level and black level to be
the same level.
5. Connect an oscilloscope to test point “
TP501
” (+) and
chassis ground (-).
6. Select item no. “
1
” and change data value to adjust
the pedestal level and black level to be the same
level.
7. Connect an oscilloscope to test point “
TP561
” (+) and
chassis ground (-).
8. Select item no. “
2
” and change data value to adjust
the pedestal level and black level to be the same
level.
Pedestal Lebel = Black Lebel
PC Pedestal adjustment
1. Receive the a6-step gray scale computer signal with
Input 1 [COMPUTER]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP3671
” (+)
and chassis ground (-).
4. Select group no. “
11
”, item no. “
3
” and change data
value to adjust amplitude “a” to be
2.0
±0.1V.
5. Select item no. “
4
” and change data value to adjust
amplitude “b” to be
7.5
±0.1V.
(a)
(b)
GND
NRS adjustment
1. Receive the 16-step gray scale computer signal with
Input 1 [COMPUTER]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
11
”, item no. “
8
” and change data
value to adjust amplitude “a” to be
10.0
±0.1V.
5. Connect an oscilloscope to test point “
TP501
” (+)
and chassis ground (-).
6. Select item no. “
9
” and change data value to adjust
amplitude “a” to be
10.0
±0.1V.
7. Connect an oscilloscope to test point “
TP561
” (+)
and chassis ground (-).
8. Select item no. “
10
” and change data value to adjust
amplitude “a” to be
10.0
±0.1V.
(a)
black level
black level
Black Level adjustment
1. Receive the 16-step gray scale computer signal with
Input 1 [COMPUTER]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
10
”, item no. “
3
” and set data value
to “600”, and then decrease data to adjust waveform
“a” to be minimum amplitude.
5. Connect an oscilloscope to test point “
TP501
” (+)
and chassis ground (-).
6. Select item no. “
4
” and set data value to “600”, and
then decrease data to adjust waveform “a” to be mini-
mum amplitude.
7. Connect an oscilloscope to test point “
TP561
” (+)
and chassis ground (-).
8. Select item no. “
5
” and set data value to “580”, and
then decrease data to adjust waveform “a” to be mini-
mum amplitude.
White Level
(a)
PC Gain adjustment
Summary of Contents for PLV-70
Page 57: ... 57 CXA2150 RGB Matrix IC4501 IC Block Diagrams BH3540 Volume Control IC1652 ...
Page 58: ... 58 CXA2151 RGB Matrix IC4001 FA5332M P F Controller IC601 IC Block Diagrams ...
Page 62: ... 62 ML60851 USB I F IC9801 IC Block Diagrams LB1641 Motor Drive IC1602 IC1611 ...
Page 63: ... 63 M62399 D A IC3501 IC3551 IC Block Diagrams M62392 D A IC2381 ...
Page 64: ... 64 IC Block Diagrams SII161ACT DVI I F IC8001 PW365 System Control Scan Converter IC301 ...
Page 65: ... 65 TB1274AF Video Decoder IC3101 IC Block Diagrams STR Z2156 Power Switching IC651 ...
Page 66: ... 66 IC Block Diagrams TDA7056 Audio Output IC1631 IC1632 TC90A69F Digital Comb Filter IC2101 ...
Page 67: ... 67 uPD64083 3D Y C Separation IC1101 ...
Page 98: ...M4L 7000 Mechanical Parts List 98 51 a 51 43 43 51 b 23 a 23 b 23 ...
Page 101: ...M4L 7000 101 Optical Parts List 58 45 45 ...
Page 103: ...M4L 7000 103 ...
Page 104: ... M4LA Sep 2002 BB 400 Printed in Japan SANYO Electric Co Ltd ...