-7-
■
Lamp Replacement
The LAMP REPLACE indicator will light yellow when
the total lamp used time reaches 2000 hours. This is
to indicate that lamp replacement is required.
The total lamp used time is calculated by using the
below expression,
Total lamp used time =
T
eco
+
T
normal
x 2
T
eco
: used time in the Eco mode
T
normal
: used time in the Normal mode
You can check the lamp used time following to the
below procedure.
1
Press and hold the
POWER ON-OFF
button on the
projector for more than 20 seconds.
2
The projector used time and lamp used time will be
displayed on the screen briefly as follows.
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open
the lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1
Turn off the projector and disconnect the AC cord. Allow the projec-
tor to cool for at least 45 minutes.
2
Loosen 1 screw with a screwdriver and remove the lamp cover.
3
Loosen 2 screws and pull out the lamp assembly by grasping the
handle.
4
Replace the lamp with a new one and tighten the 2 screws back into
position. Make sure that the lamp is set properly. Replace the lamp
cover and tighten the screw.
5
Connect the AC cord to the projector and turn on.
6
Reset the Lamp Replace Counter, see below explanation
.
Note:
- The projector cannot be turned-on with lamp cover removed,
because when the lamp cover is removed, the lamp cover switch is
also released to switch off the lamp circuit.
1
Turn the projector on, press the
MENU
button and
the On-Screen Menu will appear. Press the
Point
Left/Right
button to move the red frame pointer to
the Setting Menu icon.
2
Press the
Point Down
button to move the red frame
pointer to the Lamp counter reset item and then
press the
SELECT
button. The message "Lamp
replace counter Reset?" is displayed. Move the
pointer to [Yes] and then press the
SELECT
button.
3
Another confirmation dialog box appears and select
[Yes] to reset the Lamp replace counter.
Recommendation
Should the air filter become clogged with dust par-
ticles, it will reduce the cooling fan’s effectiveness and
may result in internal heat build up and short lamp life.
We recommend cleaning the air filter after the projec-
tion lamp is replaced.
Refer to “Air Filter Cleaning”.
Counter
Projector
525H
Lamp
Normal
150H
Eco
375H
Total
675H
Total lamp used time
How to reset Lamp Replace Counter
How to check Lamp used time
ORDER REPLACEMENT LAMP
Type No. Service Parts No.
POA-LMP55 610 309 2706
Lamp
Lamp Cover
Screw
Screw
Handle
Screw
Projector used time
Summary of Contents for PLC-XU48
Page 32: ...KD6 XU4800 Electrical Parts List 32 Key No Part No Description Key No Part No Description ...
Page 36: ...KD6 XU4800 36 L2 Prism LCD panel Ass y Mechanical Parts List L2 c L2 a L2 b L2 e L2 d L2 ...
Page 39: ...KD6 XU4800 39 Mechanical Parts List ...
Page 40: ... KD6A Aug 2005 BB 400 Printed in Japan SANYO Electric Co Ltd ...