-9-
Chassis Description
error
error code
error Infomation
(See Powe Failure Detection Tree)
Normal
0
-
Power Failure
1000
MAIN, 1,8/1.V
1001
MAIN, S-5V
100
FPGA, S1.
1003
MAIN, 15/9/5V
1004
MAIN, S5/S9/S1V
1005
PJ_N/AV, 3.3/S5V
1006
FAN1, FANLOCK
1007
FAN, FANLOCK
1008
FAN3, FANLOCK
1009
FAN4, FANLOCK
1010
FAN5, FANLOCK
1011
FPGA, CONFIG
Temperature Error
000
Sensor A detects abnormal temperature.
001
Sensor A fails measurement.
100
Sensor B detects abnormal temperature.
101
Sensor B fails measurement.
10
Sensors B-A temperature error.
00
Sensor C detects abnormal temperature.
01
Sensor C fails measurement.
0
Sensors C-A temperature error.
Lamp Error
3000
Lamp1 fails on
3001
Lamp1 goes out
300
Communication Error on Lamp1
Filter Error
4000
Air Filter Clogged
Error History Log
This projector provides the error history log function. To check the logs, you need to enter the service mode and select
Group No. "0" and Item No. "0" to "49". The error code is displayed on the Data column. The description of the error
code is listed on the table below.
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Opera-
tion".
Group No. Item No.
data (error code)
(See table below)
0
0
]
<- Latest Error
1
]
]
3
]
.
]
.
]
.
]
48
]
49
]
How to clear the error History Log
1. Enter the Service Mode, and select Group No. "0" and Item No. "50".
The history log will be claered when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".