-9-
Electrical Adjustments
2
Shootout Mode
0
0 ~ 1
0: Disable 1: Enable
3
Cooling Time
3
0 ~ 15
Set cooling period, 1: 30 sec. 3: 90 sec. 15: 450 sec. 0: continuos
4
Hi-Land SW
0
0 ~ 1
0: Normal 1: Highland mode (Fan spin speed max.)
5
V-Douki SW
0
0 ~ 1
0: Synchronized Vertical 1: non-synchronized Vertical
6
Lamp Total Time
-
0 ~ 65535
Read only
7
Net Board RESET
1
0 ~ 1
0: Disable 1: Enable
8
Keystone Option
0
0 ~ 1
0: Maximum correction (fix) 1: Changeable for Input signal
9
Syukka SW
0
0 ~ 10
Set 10 to Shipping Condition
10
Color Shading SW
1
0 ~ 1
0: OFF 1: ON
11
RC Enable/Disable
0
0 ~ 3
0: Both enable 1: Front Disable 2: Rear Disable 3: Both Disable
12
Lamp Dim Level
15
0 ~ 15
0: the darkest 1: the brightest
13
Lamp Warning Time
1500
0 ~ 65535
Unit = hour
14
Forced NOBRAND
0
0 ~ 1
0: Normal 1: No brand
15
Forced Video Mute Off
0
0 ~ 1
0: Video Mute ON 1: Video Mute OFF
16
ANZEN FAN Control Fix SW
0
0 ~ 4
0: Normal 1: Normal min. 2: Normal max 3: Eco min. 4: Eco max
17
DJTR_SW
-
-
Not used
18
HDCP Option
0
0 ~ 3
0: XGA 1: Not XGA
19
HDCP Reset
0
0 ~ 10
Set 10 and write EDID Data for HDCP
20
Auto PC Adj.
0
0 ~ 1
0: Auto PC adj available, 1: Auto PC adj. not available
Group: 11 FAN (Fan Control)
0
FAN_TEMP_A_WARNING
460
30 ~ 1000
Temperature to judge abnormal A (Not memorized) Inside projector
1
FAN_TEMP_B_WARNING
800
30 ~ 1000
Temperature to judge abnormal A (Not memorized) Lamp
2
FAN_TEMP_C_WARNING
510
30 ~ 1000
Temperature to judge abnormal A (Not memorized) LCD Panel
3
FAN_TEMP_B-A_WARNING
520
0 ~ 1000
4
FAN_TEMP_C-A_WARNING
200
0 ~ 1000
5
FAN_CONTROL_SW
0
0 or 1
0: Auto-control all Fans 1: Manual control all Fans
6
FAN1 Manual Out
1350
0 ~ 2000
These are effective when FAN_CONTROL_SW is set to "1".
7
FAN2 Manual Out
1350
0 ~ 2000
8
FAN4 Manual Out
1350
0 ~ 2000
9
FAN5 Manual Out
1350
0 ~ 2000
10
FAN6 Manual Out
1350
0 ~ 2000
11
FAN7 Manual Out
1350
0 ~ 2000
12
FAN1 Now Out
-
Read only Reading voltage of each Fan
13
FAN2 Now Out
-
14
FAN4 Now Out
-
15
FAN5 Now Out
-
16
FAN6 Now Out
-
17
FAN7 Now Out
-
18
Temp Monitor A
-
-
Read only
19
Temp Monitor B
-
-
20
Temp Monitor C
-
-
21
Pressure Monitor
-
-
Read only
22
FAN_BALLAST_SW
0
0 or 1
Fan control depend on Ballast Output Voltage 0: OFF 1: ON
23
Service Target MODE
-1
-1 ~ 3
-1: Current Mode 0: Normal Mode 1: Eco Mode
24
Service Target FAN
0
0 ~ 5
Service taget 0: FAN1 1: FAN2 2: FAN4 3: FAN5 4: FAN6 5: FAN7
✻
Fan adjustment [Setting]
25
Control Switch
0
Control Switch for the operated Fan 0: Auto 1: Manual
26
Temp Source Range High
400
Control range of Temperature for Temperature Sensor A
27
Temp Source Range Low
330
28
Temp Fan-Out Range High
1350 / 1000
Control range of Fan control voltage by Temperature Sensor A
29
Temp Fan-Out Range Low
780 / 700 / 1000
30
Diff (UP)Src Range High
180
Difference of temperature between temp-A and temp-C for Fan additional voltage (upward)
31
Diff (UP)Src Range Low
150
32
Diff(DWN)Src Range High
80
Difference of temperature between temp-A and temp-C for Fan additional voltage (downward)
33
Diff(DWN)Src Range Low
60
34
Press Source Range Low
Control range of Pressure Sensor
35
Press Source Range High
36
Press FanAdd Range High
0
Control range of Fan additional voltage by Pressure sensor
37
Press FanAdd Range Low
500
38
Ceil-Add
Fan additional voltage when ceiling
39
Fan Out Limit Volt MAX
1400
Limit voltage of current Fan output voltage
40
Fan Out Limit Volt MIN.
650
41
Fan Out Limit DAC MAX
0 ~ 255
Limit of DAC output for current Fan
✻
Fan adjustment [max.]
42
Fan Out Limit DAC MIN.
0 ~ 255
✻
Fan adjustment [min.]
43
Manual Out
0 ~ 2000
Output voltage of current Fan at manual mode
44
Now Out
-
Reading voltage of current Fan
Group: 12 PC Real / AV Cinema
0
PC Real Contrast
32
0 ~ 63
1
PC Real Brightness
32
0 ~ 63
2
PC Real Color
32
0 ~ 63
3
PC Real Tint
32
0 ~ 63
4
PC Real Red
32
0 ~ 63
5
PC Real Green
30
0 ~ 63
No.
Adjustment Item
Initial Value
Range
Input source / Description