-49-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range Note
26 Eco Fan3 Min
Fan voltage value at Eco (unit: 0.1V)
55
60
60/75
65/80
0-255
On1/On2
27 Eco Fan3 Max
135
135
115
115
0-255
PLC-XK2600
Group
254
Fan Control Range Setting (temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp
33
35
33/34
35/36
-
On1/On2
1 High Fan Control Max Temp
40
46
40/42
43/44
-
On1/On2
2 High Fan1 Min
68
68
83/93
85/95
-
On1/On2
3 High Fan1 Max
135
135
135
135
-
4 High Fan2 Min
75
85
88/100
98/110
-
On1/On2
5 High Fan2 Max
100
105
113/125 118/130
-
On1/On2
6 High Fan3 Min
80
85
85/100
90/105
-
On1/On2
7 High Fan3 Max
135
135
135
135
-
10 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp.
at Normal
33
35
33/34
35
20-100
On1/On2
11 Normal Fan Control Max
Temp.
40
45
40/41
42/43
20-100
On1/On2
12 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
58
58
80/90
85/95
0-255
On1/On2
13 Normal Fan1 Max
135
135
135
135
0-255
14 Normal Fan2 Min
73
85
88/100 101/113
0-255
On1/On2
15 Normal Fan2 Max
96
101
112/124 117/129
0-255
On1/On2
16 Normal Fan3 Min
75
80
85/100
90/105
0-255
On1/On2
17 Normal Fan3 Max
135
135
135
135
0-255
20 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp.
at Eco
34
35
32/33
34
20-100
On1/On2
21 Eco Fan Control Max Temp
40
41
40
41/42
20-100
On1/On2
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
50
50
60/70
65/75
0-255
On1/On2
23 Eco Fan1 Max
120
120
125
125
0-255
24 Eco Fan2 Min
45
45
48/60
48/60
0-255
On1/On2
25 Eco Fan2 Max
65
70
68/80
73/85
0-255
On1/On2
26 Eco Fan3 Min
55
60
60/75
65/80
0-255
On1/On2
27 Eco Fan3 Max
110
110
115
115
0-255
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
55
0-255
1 Fan2 Initial Volt
Fan Start Voltage(0.1V)
55
0-255
2 Fan3 Initial Volt
55
0-255
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
135
0-255
5 Fan2 Cooling Speed
100
0-255
6 Fan3 Cooling Speed
135
0-255
8 Cooling Time L1
Cooling Time setting at Fan Mode L1
(x 30 sec) 1: 30, 3: 90, 15: 450 sec.
2
1-15
9 Cooling Time L2
Cooling Time setting at Fan Mode L2
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3
1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
3
1-15
11 OnStart Cooling Start Thresh-
old
38
0-100
12 After shutdown cooling
Cooling after shutdown (0: No, 1: Yes)
1
0-1
Group
256
Fan/Lamp Voltage dimmer Setting
2 Fan 1 Speed Gain
10
0-255
3 Fan 2 Speed Gain
10
0-255
4 Fan 3 Speed Gain
10
0-255
Group
257
Fan dimmer Setting
0 Dimmer Average Chech Period
Dimmer Average measurement
Time (0:10sec. 1:30sec. 2:60
sec. 90:sec...10:30sec.)
0
0-10
1 Dimmer Average
Dimmer Average Value (Read
only)
-
2 Last Voltage Difference
-
3 Voltage Difference Goal
-
Group
258
Fan Network IC temperature rising resolve
0 Standby Cooling Check Cycle
9999
1 Standby Cooling Start Threshold
9999
2 Standby Cooling Enable
9999