- 44 -
13
-5
Polarized units removal.
1. Remove 6 screws-A and remove the Polarized glass units. (See Fig.13-5)
Blue Polarized unit
5. Remove screw-E remove the plate(D) and remove
the Prepolarized glass(IN).
6. Remove 2 screws-F, remove the plates(E) and
remove the Optical filter (HCP).
7. Remove 2 screws-G, remove the plates(F) and
remove the Polarized glass (IN).
8. Remove screw-H, and remove the Temperature
sensor (PTH901) unit.
(See Fig.13-5b)
Red and Green Polarized Units
2. Remove screw-B, remove the plate(A) and remove
the Prepolarized glass(IN).
3. Remove 2 screws-C, remove the plates(B) and
remove the Optical filter (HCP).
4. Remove 2 screws-D, remove the plates(C) and
remove the Polarized glass (IN).
(See Fig.13-5a)
Optical Unit Disassemblies
A
A
A
A
A
A
Red
Green
Blue
Temperature sensor
(PTH901)
B
D
D
Holder
Plate (A)
Plate (C)
Plate (C)
Plate (B)
Plate (B)
Prepolarized
glass (IN)
Polarized
glass (IN)
C
C
Optical
filter(HCP)
E
G
G
H
Plate (D)
Plate (F)
Plate (F)
Plate (E)
Plate (E)
Temp. sensor unit
(PTH901)
Prepolarized
glass (IN)
Polarized
glass (IN)
F
F
Optical filter(HCP)
Fig.13-5
Fig.13-5a
Fig.13-5b
Summary of Contents for PLC-XF46E
Page 103: ... 103 IC Block Diagrams CXA2151Q RGB Matrix IC2261 CXD2064Q 3 Line Y C Separator IC2101 ...
Page 106: ... 106 IC Block Diagrams Sii169ACT DVI Interface IC8001 PW365 Scan Converter IC301 ...
Page 159: ... 159 MEMO ...
Page 160: ... PLC XF46N E MAY 2006 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Page 186: ...Diagrams Drawings PLC XF46N XF46E ...