-7-
Electrical Adjustment
GROUP NO. ITEM
FUNCTION
RANGE
INITIAL VALUE
NOTE
130
75 ohm Terminate / Analog filter
0 TERM_1
(1) 75 ohm terminate On / Off (0: Off, 1: On)
(2) Analog filter On/Off (0: Off, 1: On) on Input board side
0 / 1
0
1 TEMR_2
Analog filter On/Off (0: Off, 1: On) on Main Board side
0 / 1
0
131
DVI Equalizer Boost Setting
0 CH0 Boost Data
0 ~ 7
2
1 CH1 Boost Data
0 ~ 7
2
2 CH2 Boost Data
0 ~ 7
2
140
Fan Output Level
* Fan Driving Voltage Adj.
0 Fan A Min
0 ~ 255
210
1 Fan A Max
0 ~ 255
48
2 Fan B Min
0 ~ 255
159
3 Fan B Max
0 ~ 255
36
4 Fan C Min
0 ~ 255
169
5 Fan C Max
0 ~ 255
48
6 Fan D1 Min
0 ~ 255
196
7 Fan D1 Max
0 ~ 255
34
8 Fan D2 Min
0 ~ 255
193
9 Fan D2 Max
0 ~ 255
31
10 Fan E Min
0 ~ 255
218
11 Fan E Max
0 ~ 255
38
141
Fan Option
0 Fan Output Level
0 : Max / 1: Factory / 2 : Auto / 3 : Min / 99: Menu
0 ~ 3, 99
1 (Shipment:99)
1 Fan Cooling Mode
0: Default, 1: FAN_C _MAX Fixed
0 ~ 1
0
160
Pressure Sensor Calibration
0 Press Offset
-1023 ~ 1023
0
1 Press Calib Effective Diff
0 ~ 1023
120
2 Press Sensor Calibration Error Log
0: Executed OK
10: Out of Range at Minmum
20: Out of Range at Maxmum
99: Calibration Not Executed
-
99
170
Flow Sensor
0 Flow Sensor Calibration
Flow Sensor Offset Calibration
Execute auto-calibration when the value is set to 1
0 ~ 1
0
* Filter Calibration Adj.
1 Flow Sensor Offset Minimum
Flow Sensor Minimum Offset Value
0 ~ 1023
0
2 Flow Sensor Offset Maximum
Flow Sensor Maximum Offset Value
0 ~ 1023
0
3 Flow Sensor Calibration Error Log
Auto-calibration Error Log
0: No Error
10: Unstabled at Minimum
11: Out of Range at Minimum
20: Unstabled at Maximum
21: Out of Range at Maximum
-
-
4 Clog Check Enable
Clogged Detection with Flow Sensor
0: Disable, 1: Enable
0 ~ 1
0 (Shipment: 1)
171
Flow Sensor
0 Ideal Flow Data
Read only
-
1 Flow Difference Data
Read only
-
2 Clog Detect Flow Difference Data
Read only
-
3 Warn Detect Flow Difference Data
Read only
-
4 Press Add Data
Read only
-
5 Filter Scroll Timer
(Filter used time) Read only
-
175
Filter
0 Take up Bend
Remove the filter bending
0 ~ 1
0
1 Take up Bend
Remove the filter bending
0 ~ 1
0
2 Take up Times
Filter Scroll Remaining Times (Read only)
9
3 Take up Time Reset
Reset the Filter Scroll Times
Reset when the value reaches 10
0 ~ 10
0
4 Scroll Counter Reset Time
Reset Times of Scroll Counter
0 ~ 255
0
176
Filter Display
0 Filter Icon display
0 : disable / 1 : Enable
0 / 1
1
177
Filter Timer Reset
0 Filter Counter Reset Times
User Menu Filter Counter Reset Times
0 ~ 255
0
180
DDC Setting
0 HDCP EDID Data Setting
0 : EDID Data for DVI / 1 : EDID Data for HDCP
0 / 1
1
1 DDC Data Automatic Renewal
0 : Enable / 1 : Disable
0 / 1
0
190
Panel Life Test Pattern Display
0 Panel Life Test Pattern
0 : White 73% Raster Step Pattern Display / 1 : Normal
0 / 1
1
280
CXA7007
0 G SIG Center
0 ~ 63
32
1 B SIG Center
0 ~ 63
32