-43-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
.. ..
-
..
49 Warning Log_50
-
0-3767
50 Warning Log Reset
-
0-10
Group
250
FAN Control
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
7
0 - 55
1 FAN1 MAX ADJUST (DAC)
4
0 - 55
FAN MIN ADJUST (DAC)
13
0 - 55
3 FAN MAX ADJUST (DAC)
11
0 - 55
4 FAN3 MIN ADJUST (DAC)
13
0 - 55
5 FAN3 MAX ADJUST (DAC)
4
0 - 55
Group
251
Filter detection setting
0 Filter Warning Calibration
0
0-1
1 Filter Warning Offset Optio-0
1731
0000-9999
Filter Warning Offset Optio-1
686
0000-9999
3 Filter Warning Offset Optio-
3456
0000-9999
4 Filter Warning Offset Optio-3
4139
0000-9999
5 Filter Warning Offset Optio-4
478
0000-9999
6 Filter Warning Offset Optio-5
51
0000-9999
7 Filter Warning Offset Optio-6
5607
0000-9999
8 Filter Warning Offset Optio-7
5899
0000-9999
9 Not Used
10 Not Used
11 Not Used
1 Not Used
13 Filter Warning Times
3
0-10
14 Fan-Add Filter Level 1
1000
0000-9999
15 Fan-Add Filer Level
000
0000-9999
16 Filter Warning Calibration Range
1
0-10
17 Filter Warning Calibration Time
0-10
18 Filter Warning Calibration Error Log
55
0-55
19 Filter Warning High Land Calibration Error Log
55
0-55
0 Fliter Warning Calibration Temp
60
-
1 Filter Warning Inclination Rpm (to 6˚C)
60
0000-9999
Filter Warning Inclination Rpm (over 6˚C)
80
0000-9999
3 Filter Warning Add Offset Rpm
-
-
Group
252
Fan Option
0 Fan Max SWITCH
0: Normal, 1: Max (13.5V)
0
0 - 1
1 SAFETY SWITCH
For test purpose
0
0 - 6
FAN MANUAL SWITCH
0: Auto, 1: Manual
0
0 - 1
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
100
0 - 145
4 FAN MANUAL VOLTAGE
100
0 - 145
5 FAN3 MANUAL VOLTAGE
100
0 - 145
6 FAN4 MANUAL VOLTAGE
100
0-55
7 FAN5 MANUAL VOLTAGE
100
0-55
8 FAN6-8 MANUAL DUTY
-
0-511
9 All Fan MaxMin Control
0
0 - 6
10 Press Data
Group
253
Fan tem error Setting (Memorized)
Normal
Ceiling
0 Temp A Warning (High)
Temp. A to judge the Temp Error at
High (Room)
46
46
30-100
1 Temp B Warning (High)
Temp. B to judge the Temp Error at
High (Panel)
6
6
30-100
Temp C Warning (High)
Temp. C to judge the Temp Error at
High (Lamp)
6
6
30-100
3 Temp B-A Warning (High)
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
100
100
0-100
4 Temp C-A Warning (High)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
100
100
0-100
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
46
46
30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
6
6
30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
60
60
30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
Summary of Contents for PLC-WXU700A
Page 67: ... 67 IC Block Diagrams FA7701 DDC Control IC7841 FA7703 Fan Power Control IC7811 Component2 ...
Page 68: ... 68 IC Block Diagrams MP2106 DC DC Converter IC5721 IC8018 IC8019 FA5502 P F Control IC601 ...
Page 70: ... 70 IC Block Diagrams L3E07111 LCD Driver Gamma Correction IC401 LM4889 Audio Output IC5031 ...
Page 72: ... 72 IC Block Diagrams STR Z2156 Power OSC IC651 TE7783 Parallel I O Expander IC1802 ...
Page 114: ... KY7AE November 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...