-18-
■
Optical Adjustments
[Before Adjustment]
- Input a 100% of black raster signal.
1
Loosen a screw
A
(
Fig.1-1/1-2
) on the polarized glass mounting
base which you intend to adjust.
2
Turn the polarized glass mounting base as shown in
Fig.1-1
to
obtain the darkest brightness on the screen.
3
Tighten the screw
A
to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
B-Polarized Glass
Mounting Base
R-Polarized Glass
Mounting Base
G-Polarized Glass
Mounting Base
A
A
A
Fig.1-
2
Fig.1-
1
Polarized
glass
mounting base
Main Board
A
Contrast adjustment
Before taking optical adjustments below, remove the Cabinet Top following to the “Mechanical Disassemblies”.
Adjustments require a 2.0mm hex wrench and a slot screwdriver. When you adjust Integrator lens or Relay lens
adjustment, you need to disconnect FPC cables of LCD panels on the main board.
Optical adjustment requires a 2.0mm hex wrench and a slot screwdriver.
Note: Do not disconnect connectors on the main board, because the projector cannot turn on due to operate the
power failure protection.