PLC-HF10000L Expand Serial Command Functional Specifications
31/105
8.5.9 CF_PCSTORE Command
Command
“CF_PCSTORE_%1” [CR]
%1
“MODE1” --------------------------- Store current PC Adjust status to Mode1
“MODE2” --------------------------- Store current PC Adjust status to Mode2
“MODE3” --------------------------- Store current PC Adjust status to Mode3
“MODE4” --------------------------- Store current PC Adjust status to Mode4
“MODE5” --------------------------- Store current PC Adjust status to Mode5
“MODE6” --------------------------- Store current PC Adjust status to Mode6
“MODE7” --------------------------- Store current PC Adjust status to Mode7
“MODE8” --------------------------- Store current PC Adjust status to Mode8
“MODE9” --------------------------- Store current PC Adjust status to Mode9
“MODE10” ------------------------- Store current PC Adjust status to Mode10
Details
Store current value of PC Adjust (each parameter status such as Total dots) to
Mode1-10. This command operates the same way as storing to Mode1-10 in PC
Adjust Menu.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal
8.5.10 CF_PCMODEFREE Command
Command
“CF_PCMODEFREE_%1” [CR]
%1
“MODE1” --------------------------- Set Mode1 to Free status
“MODE 2” --------------------------- Set Mode2 to Free status
“MODE 3” --------------------------- Set Mode3 to Free status
“MODE 4” --------------------------- Set Mode4 to Free status
“MODE 5” --------------------------- Set Mode5 to Free status
“MODE 6” --------------------------- Set Mode6 to Free status
“MODE 7” --------------------------- Set Mode7 to Free status
“MODE 8” --------------------------- Set Mode8 to Free status
“MODE 9” --------------------------- Set Mode9 to Free status
“MODE 10” ------------------------- Set Mode10 to Free status
Details
Delete the data registered in Custom Mode1–10 and returns it to Free status. This
command operates the same way as storing to Mode1-10 in PC Adjust Menu.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal