3
effect.
1.21 There is piece of insulator stuck on the rear chassis corresponding to the power supply board.
It is used to isolate the cool part from the hot part. Please take care to keep it intact lest it should
become a potential safety trouble.
1.22 In addition to plasma screen, the glass is a part of high value. It has such functions as
anti-radiation, adjustment of color temperature etc. Please handle it carefully.
Alignment instructions
1. Test equipment
VG-848 (YPbPr,VGA signal generator)
VG-849 (HDMI signal generator)
CA100 (white balancer)
2. Power test
Connect data processing board, power board and IR board according the wiring diagram, connect
the power and press “standby” button to turn on the TV.
a) Test the pin voltage of X802, the data are shown in table1:
Table1 voltage data of X802
X802
Pin1
2
3
4
5, 6
7, 8
9
10
11
Voltage
8.55~9.45V
0
4.85~5.35V
0
11.4~12.6V 0 4.85~5.35V 0 >2.5V
b) Test the pin voltage of XV03, the data are shown in table2:
Table2 voltage data of XV03
XV03
Pin1, 2
3, 4, 5
Voltage 23.8~25.2V
0
c) Test the pin voltage of X101, the data are shown in table3:
Table3 voltage data of X101
Note: the above data are for 42” 50” PDP; the below data are for 32” PDP:
d) Test the pin voltage of X802, the data are shown in table4:
Table4 voltage data of X802
X802
Pin1
2, 3
4
5
6, 7
8, 9
10
11
12
13, 14
15
Voltage NC
>2.5 V NC
>2.5 V
0
15.5 V~16.7V
0
8.8 V~9.35 V
0
4.85 V~5.35 V
0
3. Alignment flow-chart
The alignment flow-chart is shown as fig-1
X101 Pin1
2
Voltage 31.4~32.6V
0
Summary of Contents for PDP-42XR8DA
Page 18: ...16 6 TDA1616 ...
Page 19: ...17 ...
Page 26: ...data process ...
Page 27: ...data process ...
Page 28: ...data process ...
Page 29: ...data process ...
Page 30: ...data process ...
Page 31: ...data process ...
Page 32: ...data process ...
Page 33: ...data process ...
Page 34: ...KEY IR ...
Page 35: ...power ...
Page 36: ...power ...
Page 38: ...PDP 42XR8DA ...
Page 41: ...June 2008 ...