Power Fail Circuit
When operating the Power Fail Circuit, On-Screen-Display message or LED flashing time is
shown as below.
On-Screen-Display Message
1. FAN FAIL
When the cooling fan is trouble, below message is displayed. This message is displayed for 10 seconds in
every 10 minutes.
2. TEMPERATURE FAIL
When the internal temperature exceeds normal ( approximately more than 80 degrees ), below message is
displayed for 10 seconds and the Plasma monitor will be turned off automatically.
LED Flashing
1. TEMPERATURE FAIL
: The color of LED is ‘RED’.
2. POWER FAIL
: The color of LED is ‘GREEN’.
3. SOUND AMP FAIL
: The color of LED is ‘YELLOW’.
Warning!
Internal fan is trouble, not working properly.
Warning!
Internal temperature is too high.
Time of flashing
Fail Name
2
Temperature
Time of flashing
Fail Number
1
P FAIL 1
2
P FAIL 3
3
P FAIL 1 & 3
Time of flashing
Fail Number
1
P FAIL 2
Note:
1. In case of overlapped fail, 1 to 3 is repeated in turn.
2. If power fail is detected 3 times in 15 minutes, the monitor will stop operating.
3. If pull the AC cord, the information of these fails will be disappeared.
Summary of Contents for PDP-42H1A
Page 31: ... 31 Main Scaler IC301 PW365 IC Block Diagrams Sync Separation IC8971 LA7217 T TRM ...
Page 32: ... 32 Sync Separation IC1201 BA7078AF IC Block Diagrams RGB Component Switch IC1123 24 BA7657F ...
Page 33: ... 33 Audio Video Switch IC1001 CXA1845Q IC Block Diagrams ...
Page 34: ... 34 Audio Control IC001 CXA2013N Q Sound IC002 MM1369BD IC Block Diagrams ...
Page 35: ... 35 BBE IC121 NJM2155M IC Block Diagrams Digital AMP IC071 TA1101B ...
Page 62: ... Memo ...
Page 63: ... Memo ...
Page 64: ...FEB 2002 335 Printed in Japan SANYO Electric Co Ltd ...