-13-
4. Optical Filter Removal
Cabinet Front includes Optical Filter to protect the
damage of Panel, improve picture quality, or
pre-
vent exposure of interference
.
For removal of Optical Filter, remove screws of
Fig.9.
[NOTE]
1. The Optical Filter is easy to be damaged. Do
not touch directly by hand. If there is dust,
remove it by watery neutral detergent.
2. The
gasket
(like brown tape) is sticked on the
Optical Filter. Order Optical Filter with gaskets
for service parts. Refer to parts list.
5. Servicing of Unit
(Refer to Fig.4)
For removal of Main or Audio Unit, remove screws fixed to chassis plate.
In case of Audio Unit, remove shield plate covered with Line Filters (LF1601, LF1602, LF1603).
Note :
The shield plate is soldered at left side of circuit board.
6. Servicing of Back Terminal
For removal of Connect Unit, remove 25 screws (L: 3X6) of Fig.10.
Note :
Terminal Unit (A, B) is connected to Connect Unit.
Fig. 9
■
PDP Panel Replacement
For change of PDP Panel (Module), proceed
1
to
3
.
Mechanical Disassemblies
L
L
L
L
Fig. 10
Gasket
Summary of Contents for PDP-32H1A
Page 33: ... 33 Main Scaler IC301 PW365 IC Block Diagrams Sync Processor IC8971 LA7217 T TRM ...
Page 34: ... 34 Sync Processor IC1201 BA7078AF IC Block Diagrams RGB Component Switch IC1123 24 BA7657F ...
Page 35: ... 35 Audio Video Switch IC1001 CXA1845Q IC Block Diagrams ...
Page 36: ... 36 Audio Control IC001 CXA2013N Q Sound IC002 MM1369BD IC Block Diagrams ...
Page 37: ... 37 BBE IC121 NJM2155M IC Block Diagrams Digital AMP IC071 TA1101B ...
Page 63: ... Memo ...
Page 64: ...DEC 2001 335 Printed in Japan SANYO Electric Co Ltd ...