PDG-DXL100 Expand Serial Command Functional Specifications
29 / 47
9.4 Image Status Read Commands
9.4.1
CR_BRIGHT Command
Command
“CR_BRIGHT” [CR]
Details
Get user controlled value of Brightness
Correspondence
Acceptable
“000_%1” [CR]
%1
“-50” – “050”
Unacceptable
“?” [CR]
9.4.2
CR_CONT Command
Command
“CR_CONT” [CR]
Details
Get user controlled value of Contrast
Correspondence
Acceptable
“000_%1” [CR]
%1
“-50” – “050”
Unacceptable
“?” [CR]
9.4.3
CR_COLOR Command
Command
“CR_COLOR” [CR]
Details
Get user controlled value of Color
Correspondence
Acceptable
“000_%1” [CR]
%1
“-16” – “016”
Unacceptable
“?” [CR]
9.4.4
CR_SHARP Command
Command
“CR_SHARP” [CR]
Details
Get user controlled value of Sharpness
Correspondence
Acceptable
“000_%1” [CR]
%1
“000” – “031”
Unacceptable
“?” [CR]
9.4.5
CR_GAMMA Command
Command
“CR_GAMMA” [CR]
Details
Get user controlled value of Gamma
Correspondence
Acceptable
“000_%1” [CR]
%1
“000” – “003”
Unacceptable
“?” [CR]