background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXPAND SERIAL COMMAND

 

FUNCTIONAL SPECIFICATIONS 

PDG-DXL100 

                               

 

Ver. 1.01 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SANYO Electric Co., Ltd 

DS Company 

Projector Division

 

Summary of Contents for PDG-DXL100 - XGA DLP Projector

Page 1: ...EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PDG DXL100 Ver 1 01 SANYO Electric Co Ltd DS Company Projector Division ...

Page 2: ...and Table 11 6 2 PC Status Read Command Table 11 6 3 Video Status Read Command Table 11 6 4 Input Status Read Command Table 11 6 5 Screen Status Read Command Table 11 6 6 Lamp Status Read Command Table 12 6 7 Sound Status Read Command Table 12 6 8 Setting Status Read Command Table 12 6 9 Other Status Read Command Table 12 7 Error Code Table 13 8 Functional Execution Command 14 8 1 Format 14 8 2 Tr...

Page 3: ...ommand 21 8 6 10 CF_INPUT8 Command 21 8 7 Screen Control Command 22 8 7 1 CF_SCREEN Command 22 8 7 2 CF_KEYSTONE Command 22 8 7 3 CF_MOUNTING Command 22 8 7 4 CF_DZCENT Command 22 8 8 Lamp Command 23 8 8 1 CF_LAMPH Command 23 8 8 2 CF_LAMPMODE Command 23 8 9 Sound Command 24 8 9 1 CF_VOLUME Command 24 8 9 2 CF_MUTE Command 24 8 10 Setting Command 25 8 10 1 CF_INPUTSEARCH Command 25 8 10 2 CF_LANG ...

Page 4: ...9 5 1 CR_FSYNC Command 32 9 5 2 CR_TDOTS Command 32 9 5 3 CR_H POS Command 32 9 5 4 CR_V POS Command 32 9 5 5 CR_SETPCADJ Command 33 9 6 Video Status Read Command 34 9 6 1 CR_SERSYS Command 34 9 7 CR_INPUT Command 35 9 7 1 CR_INPUT Command 35 9 7 2 CR_SOURCE Command 35 9 7 3 CR_SYSTEM Command 36 9 7 4 CR_SRCINP1 Command 36 9 7 5 CR_SRCINP2 Command 36 9 7 6 CR_SRCINP3 Command 37 9 7 7 CR_SRCINP4 Co...

Page 5: ...9 11 2 CR_LANG Command 42 9 11 3 CR_P MANETIME Command 42 9 11 4 CR_SECURITY Command 42 9 11 5 CR_PJLOCKNOW Command 43 9 11 6 CR_PJLOCKMENU Command 43 9 11 7 CR_RS232MODE Command 43 9 11 8 CR_STANDBYMODE Command 43 9 11 9 CR_CCAPTION Command 43 9 11 10 CR_FANCONTROL Command 44 9 11 11 CR_LAMPLIFERE Command 44 9 11 12 CR_RCODE Command 44 9 12 Other Status Read Commands 45 9 12 1 CR_STATUS Command 4...

Page 6: ...us and commands have to be embedded to the soft development The items are not open to the public including sales companies 2 Serial Interface Specification 2 1 Transfer Specification Items Specification Synchronous System Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity N A Stop Bit 1 Flow Control N A 1 Transmission Speed Initial setting value is 9600 2 Transmission Speed can be...

Page 7: ...succession do not send another command unless the response to the previous command has been returned need to confirm that the processing of the current command has been completed and returned the response before sending another command Command PC Projector CF_BRIGHT_032 CR Projector PC 000 CR Command processing Response A few ms 8000 ms Note When the computer sends another command before the previ...

Page 8: ...st the incoming command is represented as RESPONSE 4 2 CR Carriage Return Code The command ends with carriage return code The response also ends with carriage return code 4 3 _ Space Code All space code is indicated by _ 4 4 1 Parameter included in command When there is more than one parameter they are represented as 2 3 In this specifications Slot notation is same as Input notation Etc Slot1 Inpu...

Page 9: ... 5 3 Input Control Command Table Execute command Item CF_INPUT_ 1 CR Select Input CF_SYSTEM_ 1 CR Select System in Video or S Video input mode CF_INPUT1_ 1 CR Select Input1 and set input selected in 1 CF_INPUT2_ 1 CR Select Input2 and set input selected in 1 CF_INPUT3_ 1 CR Select Input3 and set input selected in 1 CF_INPUT4_ 1 CR Select Input4 and set input selected in 1 CF_INPUT5_ 1 CR Select In...

Page 10: ...ON OFF of Input search CF_LANG_ 1 CR Select language for OSD CF_P MANETIME_ 1 CR Set timer for Power management CF_FDEFAULT_ 1 CR Return the settings to Factory Default status CF_RS232MODE_ 1 CR Set RS232 LAN of RS232 mode CF_STANDBYMODE_ 1 CR Set Standby mode CF_CCAPTION_ 1 CR Set Closed caption CF_FANCONTROL_ 1 CR Set Fan control CF_LAMPLIFERE_ 1 CR Set Lamp life Reminder CF_RCODE_ 1 CR Select R...

Page 11: ...ion CR_V POS CR Get setting value of Vertical Position CR_SETPCADJ CR Get currently displayed signal 6 3 Video Status Read Command Table Status read command Item CR_SERSYS CR Get currently selected signal 6 4 Input Status Read Command Table Status read command Item CR_INPUT CR Get selected Input CR_SOURCE CR Get selected Source CR_SYSTEM CR Get selected System in Video Input mode CR_SRCINP1 CR Get...

Page 12: ...R Get value of time when Power management CR_SECURITY CR Get setting status of security CR_PJLOCKKNOW CR Get actual setting status of security CR_PJLOCKMENU CR Get setting status of security of menu CR_RS232MODE CR Get setting status of RS232 mode CR_STANDBYMODE CR Get setting status of Standby mode CR_CCAPTION CR Get setting status of Closed caption CR_FANCONTROL CR Get setting status of Fan cont...

Page 13: ...ding invalid value etc 000 Normal reception This is Not error 101 Specified function is not available in the selected mode 102 Specified value is out of range Not reflected 103 Command mismatched to Hardware The command is for the Optional function which is not implemented 201 Increased decreased value is out of range in the item which is specified with numerical parameter or changeable numerical ...

Page 14: ...r Code Table for detail When the projector cannot decode the command it returns CR 8 2 Transfer Example When setting projector s total dots to 1344 by Expand Command PC PJ CF_TDOTS_1344 CR PC PJ 000 CR Acceptable 8 3 Operation Requirements Functional Execution Commands are limited in the status bellow Status Read Commands are available in following status Projector Status Available Functional Exec...

Page 15: ...ble only in the normal Power ON status No display is shown when projector received command Correspondence Acceptable 000 CR Unacceptable Error Code CR 8 4 3 CF_COLOR Command Command CF_COLOR_ 1 CR 1 16 016 Directly specify setting value of Color UP Increment setting value of Color by 1 DN Decrement setting value of Color by 1 Details Set user controlled value of Color Available only in the normal ...

Page 16: ... 8 4 7 CF_IMAGE Command Command CF_IMAGE__ 1 CR 1 PRESEN Presentation Fixed value to display graphic image with Presentation BRIGHT Bright Fixed value to focus on tone reproduction for Bright MOVIE Movie Fixed value to focus on tone reproduction for Movie SRGB sRGB Fixed value to focus on tone reproduction for sRGB USER USER Fixed value to focus on tone reproduction for USER Details Select Image m...

Page 17: ...ojector received command Correspondence Acceptable 000 CR Unacceptable Error Code CR 8 4 10 CF_WHITEPEAKING Command Command CF_WHITEPEAKING_ 1 CR 1 000 010 Directly specify setting value of White peaking UP Increment setting value of White peaking by 1 DN Decrement setting value of White peaking by 1 Details Set user controlled value of White peaking Available only in the normal Power ON status No...

Page 18: ...eived command Correspondence Acceptable 000 CR Unacceptable Error Code CR 8 5 3 CF_H POS Command Command CF_H POS_ 1 CR 1 005 0005 Directly specify setting value of Horizontal Position nnnn indicates maximum value which is current value of Total Dots Display Dots UP Increment setting value of Horizontal Position by 1 DN Decrement setting value of Horizontal Position by 1 Details Set value of Horiz...

Page 19: ...TEM Command Command CF_SYSTEM_ 1 CR 1 Input is Video AUTO Select MODE 1 NTSC Select MODE 2 PAL Select MODE 3 SECAM Select MODE 4 Input is S Video AUTO Select MODE 1 NTSC Select MODE 2 PAL Select MODE 3 SECAM Select MODE 4 Details Select system of the currently selected Input Valid only when in the normal Power ON status When selected Input does not meet the requirement for the specified 1 return 1...

Page 20: ... CR 8 6 6 CF_INPUT4 Command Command CF_INPUT4_ 1 CR 1 COMPUTER2 Select Computer2 Details Select Computer2 Valid only when it is in the normal Power ON status The projector shows Image OSD at receiving the command Correspondence Acceptable 000 CR Unacceptable Error Code CR 8 6 7 CF_INPUT5 Command Command CF_INPUT5_ 1 CR 1 YPBPR 2 Select YPbPr 2 Details Select YPbPr 2 Valid only when it is in the no...

Page 21: ...Power ON status The projector shows Image OSD at receiving the command Correspondence Acceptable 000 CR Unacceptable Error Code CR 8 6 10CF_INPUT8 Command Command CF_INPUT8_ 1 CR 1 S VIDEO Select S video Details Select S video Valid only when it is in the normal Power ON status The projector shows Image OSD at receiving the command Correspondence Acceptable 000 CR Unacceptable Error Code CR ...

Page 22: ...just Details Change the correction level of Keystone distortion Valid only when in the normal Power ON status When the value reaches the correction limit the projector accepts the command but does not execute it The behavior is the same as the Keystone button of the remote control A scale OSD is shown by adjusting Keystone and the scale reflects adjusting value Correspondence Acceptable 000 CR Una...

Page 23: ...le Unacceptable Unacceptable 8 8 2 CF_LAMPMODE Command Command CF_LAMPMODE_ 1 CR 1 ON Set lamp control mode to ECO OFF Set lamp control mode to NORMAL Details Select Eco mode Valid only when in the normal Power ON status The value set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status No display is shown when projector received command...

Page 24: ...d release the sound mute function The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status Display OSD when projector received command Correspondence Acceptable 000 CR Unacceptable Error Code CR 8 9 2 CF_MUTE Command Command CF_MUTE_ 1 CR 1 ON Set Sound Mute ON OFF Set Sound Mute OFF Details Set Cancel Sound Mute Valid only wh...

Page 25: ... GRE Select Greece NOR Select Norway CZE Select Czech KOR Select Korea RUS Select Russia POR Select Portuguese HUN Select Hungarian Details Select language for OSD Valid only when in the normal Power ON status The language set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status No display is shown when projector received command Corresp...

Page 26: ...ence Acceptable 000 CR Unacceptable Error Code CR 8 10 6 CF_STANDBYMODE Command Command CF_STANDBYMODE_ 1 CR 1 ON Set Standby mode On OFF Set Standby mode Off Details Select Eco Standby mode Valid only when in the normal Power ON status The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status No display is shown when projector...

Page 27: ...ay is shown when projector received command Correspondence Acceptable 000 CR Unacceptable Error Code CR 8 10 10 CF_ RCODE Command Command CF_RCODE_ 1 CR 1 001 Select Code1 002 Select Code2 UP Switch Code setting of Remote Control forward Code1 Code2 Code1 DN Switch Code setting of Remote Control backward Code1 Code2 Code1 Details Select Code of Remote Control The status set by this command is stor...

Page 28: ...able command it returns the required information as a data string 000_ 1 CR 1 required Information a data string Refer to Basic Status Read Command Table 3 When the received data cannot be decoded the projector returns CR 9 2 Transfer Example Getting total dots of the projector by Expand Serial Commands PC PJ CR_TDOTS CR PC PJ 000_ 1344 CR 9 3 OSD Don t display OSD when projector received Status R...

Page 29: ...lue of Contrast Correspondence Acceptable 000_ 1 CR 1 50 050 Unacceptable CR 9 4 3 CR_COLOR Command Command CR_COLOR CR Details Get user controlled value of Color Correspondence Acceptable 000_ 1 CR 1 16 016 Unacceptable CR 9 4 4 CR_SHARP Command Command CR_SHARP CR Details Get user controlled value of Sharpness Correspondence Acceptable 000_ 1 CR 1 000 031 Unacceptable CR 9 4 5 CR_GAMMA Command C...

Page 30: ... for Bright MOVIE Movie Fixed value to focus on tone reproduction for Movie SRGB sRGB Fixed value to focus on tone reproduction for sRGB USER USER Fixed value to focus on tone reproduction for USER Unacceptable Error Code CR When command is invalid in the given condition CR When unknown command is received 9 4 8 CR_BRTCOLOR Command Command CR_BCOLOR CR Details Get user controlled value of Brillian...

Page 31: ... Serial Command Functional Specifications 31 47 9 4 10 CR_WHITEPEAKING Command Command CR_WHITEPEAKING CR Details Get user controlled value of White peaking Correspondence Acceptable 000_ 1 CR 1 000 010 Unacceptable CR ...

Page 32: ...005 nnnn Display Dots Horizontal Position Unacceptable Error Code CR When command is invalid in the given condition CR When unknown command is received 9 5 3 CR_H POS Command Command CR_H POS CR Details Get value of Horizontal Position Correspondence Acceptable 000_ 1 CR 1 005 0005 nnnn Total Dots Display Dots Unacceptable Error Code CR When command is invalid in the given condition CR When unknow...

Page 33: ...Details Get value of Signal name Correspondence Acceptable 000_ 1 CR 1 This command is available only Input is PC Analog Get value of Signal name 640x480 VGA1 is input 1024x768 XGA1 is input 1600x1200 UXGA1 is input Please tell us your spec about value of signal name Unacceptable CR When unknown command is received ...

Page 34: ...Get currently selected signal Valid only when input is video Invalid when Slot is computer Correspondence Acceptable 000_ 1 CR 1 1080i60 1080i 60Hz 1080i50 1080i 50Hz 1035i 1035i 720P 720p 575P 576p 480P 480p 575i 576i includes composite signal such as PAL 480i 480i includes composite signal such as NTSC NO_SIGNAL There is no signal Unacceptable CR ...

Page 35: ...ed 6 Scart is selected 7 Video is selected 8 S video is selected Unacceptable CR 9 7 2 CR_SOURCE Command Command CR_SOURCE CR Details Get selected Source Correspondence Acceptable 000_ 1 CR 1 HDMI HDMI is selected COMPUTER1 Computer1 is selected YPBPR1 YPbPr1 is selected COMPUTER2 Computer2 is selected YPBPR2 YPbPr2 is selected SCART Scart is selected VIDEO Video is selected S VIDEO S VIDEO is sel...

Page 36: ...PAL PAL is selected SECAM SECAM is selected PAL M PAL M is selected PAL N PAL N is selected 1080i60 1080i60Hz is selected 1080i50 1080i50Hz is selected 1035i 1035i is selected 720P 720p is selected 575P 575p is selected 480P 480p is selected 575i 575i is selected 480i 480i is selected Unacceptable Error Code CR When command is invalid in the given condition CR When unknown command is received 9 7 ...

Page 37: ...ommand Command CR_SRCINP5 CR Details Get Source of Input 5 Correspondence Acceptable 000_ 1 CR 1 YPBPR2 Source is YPBPR2 Unacceptable CR 9 7 9CR_SRCINP6 Command Command CR_SRCINP6 CR Details Get Source of Input 6 Correspondence Acceptable 000_ 1 CR 1 SCART Source is Scart Unacceptable CR 9 7 10 CR_SRCINP7 Command Command CR_SRCINP7 CR Details Get Source of Input 7 Correspondence Acceptable 000_ 1 ...

Page 38: ...nd is received 9 8 2 CR_KYSTNMODE Command Command CR_KYSTNMODE CR Details Get currently setting of keystone Correspondence Acceptable 000_ 1 CR 1 STR Unacceptable Error Code CR When command is invalid in the given condition CR When unknown command is received 9 8 3 CR_MOUNTING Command Command CR_MOUNTING CR Details Get currently setting of mounting Correspondence Acceptable 000_ 1 CR 1 FDESKTOP Se...

Page 39: ...Correspondence Acceptable 000_ 1 CR 1 2 00000 99999 Unacceptable CR 9 9 3 CR_LAMPMODE Command Command CR_LAMPMODE CR Details Get Lamp mode setting status Correspondence Acceptable 000_ 1 CR 1 OFF NORMAL is selected ON ECO is selected Unacceptable Error Code CR 9 9 4 CR_LAMPSTS Command Command CR_LAMPSTS CR Details Get the information of Lamp lighting status Correspondence Acceptable 000_ 1 CR 1 n ...

Page 40: ...ommand Command CR_PROJH CR Details Get total running time of projector in hours Correspondence Acceptable 000_ 1 CR 1 0000000 0099999 Unacceptable CR 9 9 6 CR_HMLAMP Command Command CR_HMLAMP CR Details Get total lamp number Correspondence Acceptable 000_ 1 CR 1 001 Unacceptable CR ...

Page 41: ... CR_VOLUME Command Command CR_VOLUME CR Details Get value of volume setting Correspondence Acceptable 000_ 1 CR 1 000 010 Unacceptable CR 9 10 2 CR_MUTE Command Command CR_MUTE CR Details Get setting status of Mute Correspondence Acceptable 000_ 1 CR 1 ON Sound mute on OFF Sound mute off Unacceptable CR ...

Page 42: ...lected ESP Spanish is selected SVE Swedish is selected CHI Chinese is selected JPN Japanese is selected POL Pohland is selected TUR Turkish is selected GRE Greece is selected NOR Norway is selected CZE Czech is selected KOR Korea is selected RUS Russia is selected POR Portuguese is selected HUN Hungarian is selected Unacceptable CR 9 11 3 CR_P MANETIME Command Command CR_P MANETIME CR Details Get ...

Page 43: ... of Security on menu Correspondence Acceptable 000_ 1 CR 1 ON Security is on in menu OFF Security is off in menu Unacceptable CR 9 11 7 CR_RS232MODE Command Command CR_RS232MODE CR Details Get setting status of RS232 mode Correspondence Acceptable 000_ 1 CR 1 RS232 RS232 is selected LAN LAN is selected Unacceptable CR 9 11 8 CR_STANDBYMODE Command Command CR_STANDBYMODE CR Details Get setting stat...

Page 44: ...d OFF Off is selected Unacceptable CR 9 11 11 CR_LAMPLIFERE Command Command CR_LAMPLIFERE CR Details Get setting status of Lamp life Reminder Correspondence Acceptable 000_ 1 CR 1 ON On is selected OFF Off is selected Unacceptable CR 9 11 12 CR_RCODE Command Command CR_RCODE CR Details Get selected Remote Control Code Correspondence Acceptable 000_ 1 CR 1 001 Code1 is selected 002 Code2 is selecte...

Page 45: ...21 Cooling after Lamp Error Unacceptable CR 9 12 2 CR_SIGNAL Command Command CR_SIGNAL CR Details Get status if there is any signal or not Correspondence Acceptable 000_ 1 CR 1 ON There is signal OFF There is no signal Unacceptable CR 9 12 3 CR_VMUTE Command Command CR_VMUTE CR Details Get No Show setting status Correspondence Acceptable 000_ 1 CR 1 ON No Show is ON OFF No Show is OFF Unacceptable...

Page 46: ...mal status occurs Possible to get the data from plural sensors at once Correspondence Acceptable 000_ 1 CR 1 e g _31 5F CR _ indicates a space When the temperature goes under 0 the first character become such as 05 5F With more than one temperature sensors installed projector returns the data of each sensor in order e g _31 5F_35 2S CR The first data indicates sensor 1 then sensor 2 data follows a...

Page 47: ...erature Temperature is low enough and safe N Applicable sensor does not detect abnormal temperature E Not able to return temperature data When several sensors are incorporated projector returns values continuously Etc _31 5F__35 2S CR A data of sensor 1 comes first and a data of sensor 2 follows after single space As described respectively in e g sensor 1 detects abnormal temp sensor 2 detects 35 ...

Reviews: