-43-
Electrical Adjustment
White 100%
Black 100%
Black and noisy
image appears
[3] Manual adjustment (component)
Input mode
Video mode (Input -Component)
Input signal
100% color bar signal (480i)
1. Select Group "
260
", No. "
100
" and set data value to "
4
".
. Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group
No.
Adjustment
10 -
3
Y Gain
3. Select Group "
260
", No. "
100
" and set data value to "
5
".
4. Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group
No.
Adjustment
0
-
3
Y Gain
5. Select Group "
260
", No. "
100
" and set data value to "
0
".
[2] Manual adjustment (Slot)
Input mode
Computer mode (Input 3)
Input signal
16-step gray scale computer signal
Slot board
Analog RGB input board equipped
1. Select Group "
260
", No. "
100
" and set data value to "
2
".
. Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group
No.
Adjustment
10 -
3
ADC-Green Gain
10 -
4
ADC-Red Gain
10 -
5
ADC-Blue Gain
3. Select Group "
260
", No. "
100
" and set data value to "
0
".
When the PC, Video or Component Auto Calibration
fails, take the following manual adjustment instead of
auto calibration.
[1] Manual adjustment (Pc)
Input mode
Computer mode
Input signal
16-step gray scale computer signal
1. Select Group "
260
", No. "
100
" and set data value to "
1
".
. Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group
No.
Adjustment
10 -
3
ADC-Green Gain
10 -
4
ADC-Red Gain
10 -
5
ADC-Blue Gain
3. Select Group "
260
", No. "
100
" and set data value to "
3
".
4. Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
Group
No.
Adjustment
0
-
3
ADC-Green Gain
0
-
4
ADC-Red Gain
0
-
5
ADC-Blue Gain
5. Select Group "
260
", No. "
100
" and set data value to "
0
".
W
Y
C
G
M
R
B
BK
Black and noisy
image appears
[4] Manual adjustment (Video)
Input mode
Video mode (Input -Composite)
Input signal
16-step gray scale composite video
signal
1. Select Group "
260
", No. "
100
" and set data value to "
6
".
. Adjust the data values listed in the table below as the
100% white part on the screen becomes the most
noisy (darkest).
3. Select Group "
260
", No. "
100
" and set data value to "
0
".
Group No. Adjustment
0 -
0
Y Level
PC, Video, Component Manual adjustment
Image example of manual adjustment
for [Pc / Slot / Video]
Image example of manual adjustment
for [component]
Summary of Contents for PDG-DHT100L - DLP Projector - HD 1080p
Page 45: ... 45 Electrical Adjustment Test Points and Locations K66S 1 7 ...
Page 147: ... 147 IC Block Diagrams AD8185ARUZ Slot RGB SW IC9031 THS7347IPHPR Analog SW IC1201 ...
Page 148: ... 148 IC Block Diagrams CXA2239AR Componemt SW IC2201 ISL51002CQZ A D IC201 ...
Page 149: ... 149 IC Block Diagrams BA7078AF Sync Sep IC5321 M62393FP DAC IC7801 ...
Page 150: ... 150 IC Block Diagrams EDD2516AETA RAM IC1311 IC1331 TE7783APF I O Expander IC1801 ...
Page 151: ... 151 IC Block Diagrams K4S641632K SDRAM IC3401 PW392 Scaler IC301 ...
Page 152: ... 152 IC Block Diagrams NJM2671 Motor Drive IC5581 PW610 Keystone IC2301 ...
Page 155: ... 155 IC Block Diagrams MT49H8M36BM RL DRAM IC501 IC1501 2503253 DMD Driver IC3501 IC3531 ...
Page 208: ... KT5AL Apr 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...