background image

Specifications

CD010919

Discharge

Storage

Ambient
Temperature

Nominal Capacity

Nominal Voltage

Charging Current

Charging Time

Charge

Dimensions(D)

×××××

(H)

Weight

g/

×××××
×××××

m m

inch

1400mAh

1.2V

140mA

14 to 16Hrs.

°C to +50

-22

122

°C [

°F to

°F ]

°C to +45

+32

113

°C [

°F to

°F ]

°C to +60

-4

140

°C [

°F to

°F ]

0

-20

-30

65

2.29

33.0

1.30

61.0

2.36

oz

(with tube)

Typical Characteristics

Charge

Discharge

(at high rate)

Temperature

(Charge & Discharge)

Discharge

(at low rate)

Discharge

(at high rate)

Cell Type N-1U

1.2

1.3

1.4

1.5

1.6

0

2

4

6

8

10

12

14

16

0°C/32°F

20°C/68°F

Cell Voltage (V)

Charge Time (Hrs.)

Charge : 140mA

45°C/113°F

0.6

0.8

1.0

1.2

1.4

0

2

4

6

8

10

12

14

16

(0.5 It)

(0.2 It)

(0.1 It)

Cell Voltage (V)

Discharge Time (Hrs.)

Charge : 140mA 

×

 16Hrs.

at 20°C/68°F

0.6

0.8

1.0

1.2

1.4

0

10

20

30

40

50

60

70

80

(2 It)

(1 It)

Cell Voltage (V)

Discharge Time (Mins)

Charge : 140mA 

×

 16Hrs.

at 20°C/68°F

30

40

50

60

70

80

90

100

110

-20

-10

0

10

20

30

40

50

60

Available Capacity (%)

Operating Temperature

Condition

Charge : 140mA 

×

 16Hrs.

Discharge : 280mA
 (End Volt 1.0V)

{

140

122

104

86

68

50

32

14

-4

°F

°C

                Charge Characteristics
                Discharge Characteristics

0.6

0.8

1.0

1.2

1.4

0

2

4

6

8

10

12

14

16

Cell Voltage (V)

Discharge Time (Mins)

(8 It)

(4 It)

Charge : 140mA 

×

 16Hrs.

at 20°C/68°F

Reviews: