ALARMS OPERATIONS
VIDEO SENSOR ALARM
When in the (SENSOR SET) menu, the “SENSOR ALARM” item
is set to “ON” or “AND”, a moving subject detected by the video
sensor in the selected area of the image can trigger an alarm.
Example:
If movement is detected at camera 4 (in
multi-display screen)
1
The buzzer is heard and the SELECT 4 indicator flashes.
That particular alarm output changes from OPEN to LOW
(0V).
The alarm duration and the buzzer mode (ON/OFF) are set
in the (ALARM SET) menu (see page 28).
2
The image from camera 4 and the camera number (04)
will be displayed on monitor, and SA (Sensor Alarm)
will flash at the left of the camera number.
•
If in the (MONITOR SET) menu, MULTI MODE is set to
ON, active recording is not possible.
•
If in the (MONITOR SET) menu, MULTI MODE is set to
OFF, the recording mode can be set in the (ACTIVE
REC SET) menu (see page 30).
Resetting the Alarm
•
For an alarm in full screen display mode, press the
corresponding SELECT button during the alarm operation.
•
For an alarm in multi-display screen mode, press the
corresponding SELECT button to switch to full screen display
mode, then press the same SELECT button one more time.
RECORDED PICTURES MODE ALARM
In VCR playback mode, only the alarms recorded on tape are
available.
Alarms recorded on tape
When a tape with recorded alarm triggers is played back, this
unit will trigger an alarm, and the alarm display will appear on the
concerned camera picture, but the alarm operation will not be
activated as for live pictures mode alarms.
NOTE: In VCR playback mode, if there is an external alarm or a
sensor alarm trigger, the corresponding camera
SELECT indicator will flash and the buzzer will be heard
(if BUZZER is set to ON, see page 28).
SA 04
Sensor alarm
Camera number
L8FN5/XE (MPX-MS92P GB) 2000. 8. 31
44
English