Model
HIT Power 215N
HIT Power 210N
HIT Power 205N
HIT Power 200N
(HIP-215NKHA5)
(HIP-210NKHA5)
(HIP-205NKHA5)
(HIP-200NKHA5)
Cell Number in Series
72
72
72
72
Rated Power, Watts (Pmax)
215
210
205
200
Maximum Power Voltage (Vpm)
42.0
41.3
40.7
40.0
Maximum Power Current (Ipm)
5.13
5.09
5.05
5.00
Open Circuit Voltage (Voc)
51.6
50.9
50.3
49.6
Short Circuit Current (Isc)
5.61
5.57
5.54
5.50
Cell Type
HIT
HIT
HIT
HIT
Maximum System Voltage (Voc)
600
600
600
600
Factory Installed Bypass Diodes
3
3
3
3
Mechanical Specifications
Length, mm (inches)
Width, mm (inches)
Frame Depth, mm (inches)
Weight, kg (pounds)
Electrical Specifications
16 (35.3)
1580 (62.2)
798 (31.4)
46 (1.8)
SPECIFICATIONS
Section A-A’
Figure 2 Dimensions
Dimensions
All HIT Power N Models (HIP-xxxNKHA5)
Label
Note : A module should be installed on a mounting structure rail in accordance with the following
>
Use four (4) symmetrical mounting within setting range A.
: range A
Front Side
Backside
Section B-B’
Connector (MC
TM
Plug)
negative (-)
88cm
(34.6 in)
103cm
(40.6 in)
Dimensions in mm
Mount Locations
Ground (4 places)
6 0 0 V
P V U ‑ B 5 0 . 2
I P 6 5
P V U ‑ B 5 0 . 2
Junction Box