Model

HIT Power 215N

HIT Power 210N

HIT Power 205N

HIT Power 200N

(HIP-215NKHA5)

(HIP-210NKHA5)

(HIP-205NKHA5)

(HIP-200NKHA5)

Cell Number in Series

72

72

72

72

Rated Power, Watts (Pmax)

215

210

205

200

Maximum Power Voltage (Vpm)

42.0

41.3

40.7

40.0

Maximum Power Current (Ipm)

5.13

5.09

5.05

5.00

Open Circuit Voltage (Voc)

51.6

50.9

50.3

49.6

Short Circuit Current (Isc)

5.61

5.57

5.54

5.50

Cell Type

HIT

HIT

HIT

HIT

Maximum System Voltage (Voc)

600

600

600

600

Factory Installed Bypass Diodes  

3

3

3

3

Mechanical Specifications

Length, mm (inches)
Width, mm (inches)
Frame Depth, mm (inches)
Weight, kg (pounds)

Electrical Specifications

16 (35.3)

1580 (62.2)

798 (31.4)

46 (1.8)

SPECIFICATIONS  

 

 

 

Section A-A’

Figure 2   Dimensions

 

Dimensions

All HIT Power N Models (HIP-xxxNKHA5) 

Label

Note : A module should be installed on a mounting structure rail in accordance with the following 

 

Use four (4) symmetrical mounting within setting range A. 

: range A 

Front Side 

Backside

Section B-B’

Connector (MC 

TM

 Plug) 

negative (-)

88cm 
(34.6 in)

103cm 
(40.6 in)

Dimensions in mm 

Mount Locations 

Ground (4 places) 

6 0 0 V

P V U ‑ B 5 0 . 2
I P 6 5

P V U ‑ B 5 0 . 2

Junction Box

positive (+)

Summary of Contents for HIT Power 215N

Page 1: ...with a dense opaque material such as a cardboard box during installation and handling of the modules Work only in dry conditions with dry modules and dry tools Do not stand or step on a module Do not puncture cut scratch ordamage the back sheet of a module Back sheet damage will void a module s Limited Warranty and may cause fire Never use modules with a damaged back sheet Do not allow children an...

Page 2: ...e frame If other mounting means are employed this may effect the temperature of the panel SANYO recommends the installation method and mounting profile shown in Figure 1 A module should be attached on a mount or support structure rail by metal clamps The metal clamp must fulfill the following specifications Size not less than 1 5 38 mm width Thickness not less than 0 12 3 mm Material aluminum allo...

Page 3: ...upon screw threads two or more screws or two full threads of a single screw must engage the metal All the washers illustrated in Figures 3 2 and 3 3 are required as part of the grounding connection Great care should be exercised to ensure that corrosion caused by the grounding means be avoided Corrosion can increase the resistance of the grounding connection on the module or can even cause the gro...

Page 4: ...llow the applicable codes for outdoor installation of wires in conduits Verify that all fittings are properly installed to protect wires against damage and prevent moisture intrusion DIODES Bypass Diodes When modules in series strings are partially shaded it may cause reverse voltage across cells or modules because the current from other cells in the same series is forced to flow through the shade...

Page 5: ...ted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter Cup washer Terminal cup Stainless steel or brass Star washer Stainless steel Flat washer Stainless steel Flat...

Page 6: ...aximum System Voltage Voc 600 600 600 600 Factory Installed Bypass Diodes 3 3 3 3 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds Electrical Specifications 16 35 3 1580 62 2 798 31 4 46 1 8 SPECIFICATIONS Section A A Figure 2 Dimensions Dimensions All HIT Power N Models HIP xxxNKHA5 Label Note A module should be installed on a mounting structure ra...

Reviews: