8

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

9

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

NEW 2 way gas driven VRF with electrical 

power generator

SANYO’s  ECO  G  Power  is  a  revolution  in  air 

conditioning  design.  Fitted  with  a  permanent 

magnet,  non-bearing  type  generator,  it  is  the  first 

VRF  system  that  can  supply  heating,  cooling,  hot 

water and now also a supply of electrical power.
Each  ECO  G  Power  unit  has  a  4.0kW  generator,  which 

provides  enough  electricity  to  power    8  computers  or 

other applications. 

•  Innovative  technology  that  reduces  CO

2

  emissions  by  up    to 

30%

•  Heat  pump  air  conditioning  system  providing  cooling 

 

or heating

•  Can  provide  both  electricity  and  hot  water  in  heating  and 

cooling mode

• Up to 4kW electricity generated

• Very efficient generator

•  Hot  water  provided  when  cooling  or  heating  when  outside 

ambient air temperature is above 7°C

• 22kW hot water generation capacity

• 20HP model provides 56kW cooling or 63kW heating

• Can connect to up to 36  indoor units 

• 200m maximum allowable piping length (L1) (equivalent - refer 

to technical manual)

• IU/OU capacity ratio 50 - 130%

ECO G Power - GHP with electricity generation 

& hot water supply

0

10

20

30

40

50

60

70

80

90

100

Air conditioning load (%)

4.5

4

3.5

3

2.5

2

1.5

1

0.5

0

Pr

oduc

tion of elec

tr

icit

y (kW

)

Production of electricity

Generates  from  2kW  to  4kW  depending  on  air  conditioning 
load

Dimensions ECO G Power

High power 

engine

Line linkage 

inverter

Power generator

•  permanent

 

magnet type

•     non-bearing

Double clutch 

compressor

NEW

HP

20

33

36

40

45

Model

SGP-EGW190M2G2W

SGP-EW120M2G2W

SGP-EW150M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EGW190M2G2W

SGP-EW240M2G2W

Capacity

Cooling

kW

56.0

91.50

101.00

112.00

127.00

Heating 

STD

kW

63.0

103.0

113.00

126.00

143.00

Heating  Low temp*1

67.0

109.50

120.00

134.00

142.00

Hot water

22.0

34.0

38.0

44.0

47 .00

Power generater capacity at 

rating

kW

DC 2.5 (Max 4.3)

Electricity

Cooling

kW

1.35

2.20

2.70

Heating

kW

1.01

2.02

2.55

Gas consumption

Cooling

kW

44.0 (38.3)*

68.50

75.60

88.00

104.90

Heating STD

kW

48.7 (43.0)*

76.80

84.80

97.40

101.00

Heating 

LOW

62.1 (56.4)*

98.90

109.40

124.20

121.30

COP Air conditioning only

Cooling

1.33 (1.41)*

1.29

1.23

1.18

Heating

1.34 (1.43)*

1.31

1.30

1.27

1.38

AVE

1.34 (1.42)*

1.30

1.25

1.28

Max COP (Inc generater, hot water) 

Cooling

1.78

1.81

1.80

1.78

1.69

Height

Height

mm

2,248

Width

1,800

1,800 + 100 (Min distance) + 1,800

Depth

1,000 (+60)

Weight

kg

875

1,660

1,685

1,740

1,720

Starter amperes

A

30

Pipe

Gas

Inches (mm)

1 1/8 (28.58)

1 3/8 (34.92)

1 5/8 (41.27)

Liquid

5/8 (15.88)

3/4 (19.05)

Balance

3/8 (9.52)

Pipe fuel gas 

R3/4 (bolt, thread)

Pipe exhaust drain port

mm

ø25 rubber hose

Operation sound

dB(A)

58

61

63

Indoor/outdoor capacity ratio

50-130%

Number of indoor connections*

32

48

Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. 

Please refer to tube sizing charts for pipe selections and pipe length parameters. 

Capacity Hot Water is available when outside ambient air temperature is above 7˚C.

Service Clearances for installation

Top View

Rear View

Front View

Left Side View

at least 2000

(Units: mm)

Rear

(refrigerant tubing)

Rear

(refrigerant tubing)

at

 le

as

60

0

at

 le

as

60

0

at

 le

as

10

00

at

 le

as

10

00

22

50

271

54

147
207
242
275
312

461

27

83

99

13

8

16

3

17

8

19

3

55

5

at least 

100

at least 

100

1000 (external)

1800 (external)

1040 (suspension holes)

1100 (frame width)

ø736

at least 

100

at least 

350

400

(1

69

)

22

48

    

 5 

10

14

(a

nc

ho

r p

itc

h)

1000

(anchor pitch)

at least 

350

Front View

Front View

(Single-unit installation)

(Multi-unit series installation)

Gas refrigerant pipe (Gas tube)

ø28.58

Size (mm)

ø15.88

ø9.52

ø28

ø28

ø20

ø28

ø40

G: R3/4

Rp3/4

Rp3/4

OD:

Length:

1

Liquid refrigerant pipe (Liquid tube)

2

Refrigerant balance pipe (Balance tube)

3

Exhaust gas drain hose

4

Electrical power supply port

5

Inter-unit cable port

6

Inverter cable port

7

Inverter cable port

8

Fuel gas port

9

Condensation drain opening

10

Rain and condensation outlet

11

Engine exhaust outlet

12

Suspension holes 4 - ø20

13

Anchor holes 4 - ø24

14

Segment display

15

Coolant intake (top)

16

Vent

17

Hot water intake

18

Hot water outlet

19

12

14

16

9

11

17

13

15

8

3

4

2

10

1

19

18

7
5
6

Generate  electricity  during  heating  or  cooling 

operation

Generate  electricity  and  air  conditioning  (heating  or  cooling) 
at  the  same  time  by  using  remaining  engine  power.  ECO  G 
Power can generate from 2.3 to 4.0kW electricity at a generation 
efficiency of more than 40%.

Summary of Contents for ECO G SGP-EGW190M2G2W

Page 1: ...SANYO Air Conditioners The natural choice Gas Driven VRF M Series GAS DRIVEN VRF ELECTRIC VRF COMMERCIAL SPLIT SYSTEMS ROOM AIR CONDITIONERS HEATING SOLUTIONS ...

Page 2: ... supply problems If you are short of electrical power gas heat pump could be the perfect solution Runs on gas and just needs single phase supply Enables the building s electrical power supply to be used for other critical electrical demands Reduces capital cost to upgrade power substations to run heating and cooling systems Reduces power loadings within a building especially during peak periods El...

Page 3: ...re C Gas heat pump Electric heat pump Time axis in case of the same load Outside air temperature C Electric heat pump Gas heat pump Comparison of heating capacity Heating capacity Comparison of the start times for heating operation Room temperature C Gas heat pump Electric heat pump Time axis in case of the same load Outside air temperature C Electric heat pump Gas heat pump Comparison of heating ...

Page 4: ...onsumption Cooling kW 24 50 31 60 38 30 60 90 49 00 56 10 63 20 62 80 69 90 76 60 99 20 121 80 Heating STD kW 28 10 36 10 43 00 58 00 56 20 64 20 72 20 71 10 79 10 86 00 101 00 116 00 Heating LOW 36 80 47 30 56 40 64 90 73 60 84 10 94 60 93 20 103 70 112 80 121 30 129 80 COP Cooling 1 40 1 37 1 41 1 14 1 40 1 38 1 37 1 41 1 39 1 41 1 25 1 14 Heating 1 37 1 35 1 43 1 34 1 37 1 36 1 35 1 41 1 39 1 4...

Page 5: ... STD kW 48 7 43 0 76 80 84 80 97 40 101 00 Heating LOW 62 1 56 4 98 90 109 40 124 20 121 30 COP Air conditioning only Cooling 1 33 1 41 1 29 1 23 1 18 Heating 1 34 1 43 1 31 1 30 1 27 1 38 AVE 1 34 1 42 1 30 1 25 1 28 Max COP Inc generater hot water Cooling 1 78 1 81 1 80 1 78 1 69 Height Height mm 2 248 Width 1 800 1 800 100 Min distance 1 800 Depth 1 000 60 Weight kg 875 1 660 1 685 1 740 1 720 ...

Page 6: ... 59 Nominal air flow Sound pressure 1 5 mts from the unit in free field Data referred to 50 C 80 RH OAT room condition 200 C 50 RH Data referred to 320 C 50 RH OAT room condition 260 C 50 RH The high efficiency low pressure loss total heat exchanger is made of specially treated paper to enable the unit to be as efficient as 76 during normal operation This allows system to recover both latent and s...

Page 7: ...R74GXH56B SPW U095XH SPW UR94GXH56B SPW U125XH SPW UR124GXH56B SPW U165XH SPW UR164GXH56B SPW U185XH SPW UR184GXH56B SPW U255XH SPW UR254GXH56B SPW U365XH SPW UR364GXH56B SPW U485XH SPW UR484GXH56B SPW U605XH SPW UR604GXH56B DR Type Concealed Duct SPW DR254GXH56B SPW DR364GX H56B SPW DR484GX H56B SPW DR764GX H56B SPW DR964GX H56B K Type Wall Mounted Unit SPW K075XH SPW K095XH SPW K125XH KR Type Wa...

Page 8: ...ON OFF Mode setting Fan speed setting Temperature setting Air flow direction Permit Prohibit switching Weekly programme 1 Setting is not possible when a remote control unit is present Use the remote control for setting Centralised control systems Operation with various function from central station Only ON OFF operation from central station Simplified charge ratio for each tenant Touch screen pane...

Page 9: ... to present only general particulars and shall not form any part of the contract For full installation details please contact your SANYO distributor Rating Conditions The cooling and heating capacities are based on the following conditions Cooling Indoor temperature 27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Indoor temperature 20 C DB Outdoor Temperature 7 C DB 6 C WB Printed usin...

Reviews: