Outdoor Unit :
CMH2472
Indoor Unit
:
KMHS0972
×
3
Power Supply : 230V Single Phase 60Hz
< Heating Capacity >
TH : Total Heating Capacity (BTU/h)
1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70
°
F (21.1
°
C) D.B.
: Outdoor Ambient Temp. 47
°
F (8.3
°
C) D.B. / 43
°
F (6.1
°
C) W.B.
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air
Prevention Protection during heating operation into account. For this reason, the value may vary
from the actual heating characteristics.
NOTE
RATING CAPACITY:
29,200 BTU/h
AIR FLOW RATE:
847 CFM
OUTDOOR
INDOOR
ENT. TEMP.
°
F (
°
C)
AMBIENT TEMP.
°
F (
°
C)
W.B.
60
65
70
75
80
(15.6)
(18.3)
(21.1)
(23.9)
(26.7)
0 (-17.8)
TH
16,550
16,540
16,510
16,470
16,420
3 (-16.1)
TH
17,100
17,080
17,050
17,010
16,960
8 (-13.3)
TH
18,390
18,370
18,340
18,300
18,250
13 (-10.6)
TH
19,730
19,710
19,680
19,640
19,580
18 (-7.8)
TH
21,200
21,180
21,150
21,100
21,040
23 (-5.0)
TH
22,740
22,720
22,680
22,630
22,570
28 (-2.2)
TH
24,330
24,310
24,270
24,220
24,150
33 (0.6)
TH
25,970
25,950
25,900
25,850
25,770
38 (3.3)
TH
27,580
27,560
27,510
27,450
27,100
43 (6.1)
TH
29,280
29,250
# 29,200
29,130
27,660
48 (8.9)
TH
30,990
30,950
30,900
30,830
28,150
53 (11.7)
TH
32,690
32,650
32,600
31,800
28,540
58 (14.4)
TH
34,320
34,280
34,220
32,140
28,820
63 (17.2)
TH
35,970
35,930
35,860
32,330
28,990
65 (18.3)
TH
36,600
36,560
36,110
32,370
29,010
40