-8-
C7ZES
ADJUSTMENTS
IMPORTANT NOTICE
Do not attempt to adjust the following service adjustments except when adjustments are required in servicing
otherwise it may cause loss of performance and product safety.
1. Receive white raster pattern.
2. Set controls to normal.
3. Connect digital voltmetre to test point TP-B and GND.
4. Adjust voltage to 145 ±0.5V by using VR641.
1. Input and tune an RF signal which is VHF to the clear-
est station.
2. Connect digital voltmetre to test point TP-A and GND.
4. Enter the service mode and select item no. 304. AGC
TAKE OVER
5. Press the LEVEL+ or LEVEL - button to adjust volt-
age to be 3.2Vdc.
By using FOCUS VR, adjust focus control for well
defined scanning lines.
SCREEN ADJUSTMENT
1. Enter the service mode and select item no. 6.
COLLAPSED LINE
2. Turn screen VR until collapsed line is just visible and
then stop turning. Press menu key on remote control
to exit the service mode.
DRIVE ADJUSTMENT
3. Select item no.151. WPR - N (R-Drive) or 152. WPG -
N (G-Drive) and adjust both initially to 20.
4. Change data value of each item by using LEVEL + or
LEVEL - button to obtain the proper white balance.
PCC ADJUSTMENT
1. Receive cross hatch pattern and set screen mode to
“FULL”.
2. Enter the service mode and select item no. 23. EW
PARABOLA
3. Press the LEVEL+ or LEVEL - button to adjust the
vertical line to be straight.
TRAPEZOID ADJUSTMENT
1. Receive cross hatch pattern and set screen mode to
“FULL”.
2. Enter the service mode and select item no. 24.
TRAPEZIUM
3. Press the LEVEL+ or LEVEL - button to correct the
trapezum distortion of the vertical line.
PCC ADJUSTMENT
GREY SCALE ADJUSTMENT
FOCUS ADJUSTMENT
AGC ADJUSTMENT
+ B VOLTAGE ADJUSTMENT