12
3-10. Drain Hose
a)
The drain hose should be slanted downward to the
outdoors. (Fig. 28)
b)
Never form a trap in the course of the hose.
c)
If the drain hose will run in the room, insulate the
hose with insulation
*
so that chilled condensation
will not damage furniture or floors. (Fig. 29)
*
Foamed polyethylene or its equivalent is recom-
mended.
;;
;;
;;
;;;;
;;;;
;;;;
Slant
Drain
hose
Indoor
unit
Fig. 28
WARNING
Risk of Electric Shock
Do not supply power to the
unit or operate it until all tub-
ing and wiring to the outside
unit are completed.
;;
;;
;;
;;;;
;;;;
;;;;
;;
;;
;;
Condensation
Insulation material
(locally purchased)
must be used.
Fig. 29
01-386 AirCon 12/11/01 4:49 PM Page 12