-7-
THERMISTOR
Normal Reading:
Approximately 300K ohms
CONVECTION
HEATER
(BACK HEATER)
COMPONENT
CHECKOUT PROCEDURE
RESULT
Measure the resistance: Between the Pin 1 and
Pin 3 of connector S103 after disconnecting
it from the control circuit board with an
ohm-meter on the highest scale.
GRILL HEATER
(UPPER HEATER)
BLOWER
MOTOR
CONVECTION
FAN MOTOR
TURNTABLE
MOTOR
Normal Reading:
Approximately 46K ohms
Normal Reading:
Approximately 80K ohms
Normal Reading:
Approximately 389K ohms
Normal Reading:
Approximately 120K ohms
Normal Reading:
Approximately 22K ohms
Measure the resistance: After removing the lead
wires from the convection heater with an
ohm-meter on R x 1 scale.
Measure the resistance: After removing the lead
wires from the grill heater with an
ohm-meter on R x 1 scale.
Measure the resistance: After removing the lead
wires from the blower motor with an
ohm-meter on R x 100 scale.
Measure the resistance: After removing the lead wires
from the convection fan motor with an ohm-meter on
R x 100 scale.
Measure the resistance: After removing the lead
wires from the turntable motor with an ohm-meter
on highest scale.