Contents
Page
IMPORTANT!
Please Read Before Starting
..................................
2
1.
GENERAL
..........................................................
3
1-1. Tools Required for Installation (not supplied)
1-2. Accessories Supplied with Unit
1-3. Optional Copper Tubing Kit
1-4. Type of Copper Tube and Insulation Material
1-5. Additional Materials Required for Installation
2.
INSTALLATION SITE SELECTION
...................
4
2-1. Indoor Unit
2-2. Connecting Indoor Units
2-3. Outdoor Unit
2-4
Baffle Plate for the Outdoor Unit
(CLM models only)
2-5. Outer Dimensions of Outdoor Unit
2-6. Diagram of Outdoor Unit Installation
3.
INSTALLATION PROCESS
..............................
15
3-1. Embedding the Tubing and Wiring
3-2. Use of the Flaring Method
3-3. Flaring Procedure with a Flare Tool
3-4. Caution before Connecting Tubes Tightly
3-5. Tubing Connections
3-6. Insulation of Refrigerant Tubing
3-7. Taping the Tubes
3-8. Finishing the Installation
4.
AIR PURGING
...................................................
18
I
Air Purging with a Vacuum Pump (for Test Run)
I
Pump Down
5.
WIRING INSTRUCTIONS
.................................
21
5-1. General Precautions on Wiring
5-2. Recommended Wire Length and Diameter
5-3. Wiring System Diagram
5-4. How to Connect Wiring to the Terminal
5-5. Wiring Instructions for the Outdoor Unit
6.
TEST RUN
.........................................................
25
7.
CONNECTING A HOME AUTOMATION
DEVICE
.............................................................
26
8.
INSTALLATION CHECK SHEET
......................
26
INSTALLATION INSTRUCTIONS
Model Combinations
Combine indoor and outdoor units only as listed
below.
Indoor Unit
Outdoor Unit
KMS0772
CM1972
KMS0972
CM2472
KMS1272
CM3172
KMS1872
CLM1972
KMS2472
CLM2472
CLM3172
Combine indoor and outdoor units only as listed in
the combination tables for 3-room or 4-room
outdoor unit as shown in its respective manual.
Power Source:
60 Hz, single-phase, 230 / 208 VAC
– Inverter Multi Split System Air Conditioner –
COOL / DRY Model
This air conditioner uses the new refrigerant R410A.
Be sure to read the yellow instruction sheet
attached to the outdoor unit for models using the
new refrigerant R410A.
The illustrations are based on the typical appearance of
a standard model. Consequently, the shape may differ
from that of the air conditioner that you are installing.
NOTE
I
n
door
un
it A
I
n
door
un
it B
I
n
door
un
it C
I
n
door
un
it D
O
u
tdoor
un
it
Combination example
For Outdoor Unit
SANYO Commercial Solutions
In Canada
A Division of SANYO North America Corporation
SANYO Canada Inc.
Cornerstone Business Park,
1-300 Applewood Crescent, Concord
1062 Thorndale Avenue,
Ontario, L4K 5C7, Canada
Bensenville, IL 60106, U.S.A.
Refrigerant service valve size = 5/16"
NOTE
07-156 CM-CLM1972-3172 6/6/07 9:35 AM Page a