8
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Model
SA–123A
Fan Motor
Compressor
Complete Unit
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.73
5.4
6.1
Power Input
kW
0.173
1.27
1.44
Full Load Conditions Running Amps.
A
0.73
7.0
7.7
Power Input
kW
0.173
1.61
1.78
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.