Network Options
Item
Model no.
Remarks
LAN Interface Card
IPv4/IPv6, Modbus TCP supported
PRLANIF022A
When installed in the optional card slot, this card enables 24/7 monitoring of UPS operations and
status, and sends e-mail notifi cations to system administrators for quick actions via network in the
event of a power failure.
IPv4/IPv6, Modbus TCP/RTU supported
PRLANIF024A
IPv4/IPv6,
environmental monitoring supported
PRLANIF013B-US
Combined with our temperature sensor (PRLANSN001) and humidity sensor (PRLANSN002), this model
enables monitoring of UPS ambient temperature and humidity.
Dry Contact Interface Card
Terminal block output
PRCONIF005-US
This card outputs no-voltage contact signals to notify UPS status.
A and B contacts can be selected for each signal.
D-sub output connector
PRCONIF006-US
SANUPS SOFTWARE
Download version
for Windows
PMS52
□
00DL
(2)
This is an installation-based UPS management software.
For the latest OS support information, refer to our website.
For bulk purchase of software licenses, append an appropriate suffi x
to the model number as on the right.
-10
(10 licenses)
-50
(50 licenses)
-100
(100 licenses)
for Multi-OS
(1)
PMS53
□
00DL
(2)
Remote switch
RSW015
(cable length: 10 m)
RSW016
(cable length: 2 m)
This switch remotely turns on/off the UPS outlets via wired connection. It can control up to 5 UPS units
in Linked Operation. (requires optional Linked Operation cable)
Linked Operation cable
P10911
( For branching, terminal connection; between relay
connector and lead wire)
P10912
(Cable length 1 m, between relay connector and lead wire)
P10913
(Cable length 3 m, between relay connector and lead wire)
A unit-to-unit cable for performing on/off switching of multiple UPS units.
(1) Supports Windows, Unix, and Linux.
(2) The
□
’s denote revision characters.
Note: Optional products have different operating temperature ranges from the UPS.
Dimensions of Options
(Unit: mm)
■
Rack Support Rails
Used for mounting the UPS on a standard 19-inch rack.
Rack mounting brackets for securing a UPS in a rack come included or installed.A pair of left and right rails. Shown is the left rail.
■
Floor mounting brackets
Used to secure a free-standing type to the fl oor.
6-C5
2-ø1
4
353
94.9
1
8.4
1
8.1
46
261
39.7
20.5
57
△
36.5
36.5
Front side
Mass: Approx. 1.2 kg each
FMBCA01
36.5
280
Installation example - Bottom view
635
18.4
280
671.4
435
41
4-ø14
RM027-US
(3U)
RM030-US
(2U)
RM028-US
(4U)
Mass: Approx. 2.6 kg (Paired: 5.2 kg)
Mass: Approx. 2.7 kg (Paired: 5.4 kg)
Mass: Approx. 1.4 kg (Paired: 2.8 kg)
86.5
654 to 798
18
635
177.5
41
90.7
18
14.2
10
597
485
6.6
18
40
85
79
82.7
490
86.6
18
10.3
8
Rack mounting depth
555 to 913
18
635
133
41
90.7
18
14.2
10
597
Rack mounting depth
654 to 798
86.5
Rack mounting depth
23
CATALOG No.P1023B006 ‘21.6
SANUPS