Sanwa DLC460F Instruction Manual Download Page 2

Resistance measurement
Continuity check

Resistor

Continuity

below 30 ohm

5-3 Current Measurement (ACA)

Remove the test leads from the measuring 
terminals to avoid electric shock.

Remarks:

·

Clamp the conductor (cable) to measure at the 
center of the trans core (CT).

·

Clamp only one cable. If several cables are 
clamped together or 2 core or 3 core cords or 
cables are clamped, current cannot be 
measured accurately.

·

The meter may malfunction in places where a 
strong magnetic field is present.

5-4 Voltage Measurement (ACV  DCV)

Never use the meter in power lines exceeding 
600 V to ground.

5-5 Resistance Measurement, Continuity 
Check

Never apply a voltage to the input terminals.

Remarks

·

Reading is 30 ohm or below, buzzer sounds.

·

Open voltage’ approx. 0.9V

[6] MAINTENANCE

1.The following instructions are very important for 

safety. Read this manual thoroughly to ensure 
correct maintenance.

2.Calibrate and inspect the meter at least once a 

year to ensure safety and maintain its accuracy. 

6-1 Maintenance and Inspection

1) Appearance: Is the meter not damaged due to 

falling or other cause? 

2) Test leads:

Are the core wires not exposed from the 
test leads?
Is the plug when inserted to the input 
terminal not loose?

If any of the above problems exists, stop using 
the meter and request for repair.

6-2 Calibration and Inspection

For more information, please contact Sanwa

authorized agent / distributor service provider, 
listed in our website. See section 7 3.

6-3 Storage

1.  The panel and case are not resistant to 

volatile solvent and must not be cleaned with 
thinner or alcohol.

2.  The panel and case are not resistant to heat. 

Do not place the meter near heat generating 
devices.

3.  Do not store the meter in a place where it 

may be subjected to vibration or from where it 
may fall.

4.  Do not store the meter in places under direct 

sunlight, or hot, cold or humid places or 
places where condensation is anticipated.

5.  If the meter will not be used for a long time, 

remove the batteries.

6-4 Battery Replacement
Batteries when the meter is shipped:

A battery for monitoring has been installed prior to 
shipment from the factory. It may be discharged 
before the expiration of the described battery life.
*The battery for monitoring is a battery used to 
check the functions and performance of the 
product.

To avoid electric shock, do not remove the battery 
door with an input being applied to the measuring 
terminals. Also, before starting replacement, make 
sure the power of the meter is OFF.

1.  Remove the fixing screw of the battery lid with 

a minus screwdriver.

2.  Replace both two batteries in the battery 

holder with new ones. (Pay attention to their 
polarity.)

3.  Set and secure the battery door with the fixing 

screw as before.

[7] AFTER-SALE SERVICE

7-1 Warranty and Provision

Sanwa offers comprehensive warranty services to 
its end users and to its product resellers. Under 
Sanwa's general warranty policy, each instrument 
is warranted to be free from defects in 
workmanship or material under normal use for the 
period of one (1) year from the date of purchase.

This warranty policy is valid within the country of 
purchase only, and applied only to the product 
purchased from Sanwa authorized agent or 
distributor.

Sanwa reserves the right to inspect all warranty 
claims to determine the extent to which the 
warranty policy shall apply. This warranty shall not 
apply to disposables batteries, or any product or 
parts, which have been subject to one of the 
following causes:

 1. 

A failure due to improper handling or use 

that deviates from the instruction manual. 
2.

A failure due to inadequate repair or 
modification by people other than Sanwa 
service personnel. 

3.  A failure due to causes not attributable to this 

product such as fire, flood and other natural 
disaster. 

4.  Non operation due to a discharged battery. 
5.

A failure or damage due to transportation, 
relocation or dropping after the purchase.

7-2 Repair

Customers are asked to provide the following 
information when requesting services:
1.

Customer name, address, and contact 
information

2.  Description of problem
3.  Description of product configuration
4. Model 

Number

5.  Product Serial Number
6.  Proof of Date of Purchase
7.  Where you purchased the product

Please contact Sanwa authorized agent / 
distributor / service provider, listed in our website, 
in your country with above information. An 
instrument sent to Sanwa / agent / distributor 
without above information will be returned to the 
customer.

Note:

1) Prior to requesting repair, please check the 

following: Capacity of the built in battery, 
polarity of installation and discontinuity of the 
test leads.

2) Repair during the warranty period: The failed 

IEC61326
Instruction manual
Test leads (TL 23a) 

EMC Directive:
Standard 
Accessories:

meter will be repaired in accordance with the 
conditions stipulated in 7 1 Warranty and 
Provision.

3) Repair after the warranty period has expired: In 

some cases, repair and transportation cost 
may become higher than the price of the 
product. Please contact Sanwa authorized 
agent / distributor / service provider in advance. 
The minimum retention period of service 
functional parts is 6 years after the 
discontinuation of manufacture. This retention 
period is the repair warranty period. Please 
note, however, if such functional parts become 
unavailable for reasons of discontinuation of 
manufacture, etc., the retention period may 
become shorter accordingly.

4) Precautions when sending the product to be 

repaired. 

  To ensure the safety of the product during 

transportation, place the product in a box that 
is larger than the product 5 times or more in 
volume and fill cushion materials fully and then 
clearly mark 

Repair Product Enclosed

 on 

the box surface. The cost of sending and 
returning the product shall be borne by the 
customer.

7-3 SANWA web site

http://www.sanwa meter.co.jp
E mail: exp_sales@sanwa meter.co.jp

Function

Range

Accuracy

(1.2 %rdg + 5 dgt)

600.0 V

ACV

Function

Range

Accuracy

(1.0 %rdg + 2 dgt)

600.0 V

DCV

Operation method:
AC measuring
method
Display:

Sampling rate:
Over range: 
Range selection:
Polarity switching:
Low Battery
indication:

Max. clamp
conductor diameter:
Environmental
condition:

Operating
temperature:

Storage temperature:

Power supply:
Auto Power Save:

Power consumption:
Battery life:
Dimension:
Weight:

Safety standards:

Double integration
Average sensing

6000count for A/V
9999counts for Resistance 
and Continuty check
Approx. 2 times/sec.
“OL” indication
Auto
Auto (   indication)
lights when buit in battery 
voltage is below 2.2 V or 
below.
   40mm,
35mm(open CT size)
Altitude up to 2000
meters, indoor use
pollution degree 2
5     to 40    in the humidity 
range as follows.
No condensation allowed.
80%RH(max.) at 5    to 31   , 
linearly dropping from 80%RH 
to 50%RH at 31    to  40    .
  10    to 50   , 80%RH max., 
no condensation.
LR03 x 2 pcs.
Power save in about 30 
mins. after last operation.
Approx. 33 mW TYP
Approx 90 hours

H

206 x 

W83

 x 

D3

8 mm

Approx. 320 g (batteries 
included)
IEC61010 1 CAT.III 600V, 
IEC61010 2 032, IEC61010
031

[8] SPECIFICATIONS

8-1 General Specifications

Function

Range

Accuracy

(1.0 %rdg + 8 dgt)

999.9 

 7 

 8 

 9 

 10 

 11 

DC voltage
measurement

AC voltage
measurement

 6 

8-2 Measuring Range and Accuracy

Temperature: 23   5   , humidity: 80%RH max.(no 
condensation), supply voltage 2.2 V or above.
rdg(reading): Read value. dgt(digit): Number of 
counts of last digit.

AC mA current

Remarks:

Accuracy is specified at center of CT.
LPF: Approx.  3 dB@180 Hz
Accuracy assurance frequency at LPF function: 
50/60 Hz 

AC current

Function

mA

60.00 mA

600.0 mA

Range

    50 Hz / 60 Hz
    (1.2 %rdg + 5 dgt)
    40 Hz   400 Hz
    (2.5 %rdg + 10 dgt)

Accuracy

Function

ACA

60.00 A

400.0 A

Range

0 A   200 A
    50 Hz / 60 Hz
    (1.2 %rdg + 5 dgt)
    40 Hz   400 Hz
    (2.5 %rdg + 10 dgt)

200A   400A
    50 Hz / 60 Hz
    (2.0 %rdg + 5 dgt)
    40 Hz   400 Hz
    (5 %rdg + 10 dgt)

Accuracy

Remarks:

Accuracy is specified at center of CT.
LPF: Approx.  3dB@180Hz
Accuracy assurance frequency at LPF function: 
50/60 Hz  

AC voltage

Remarks:

Input impedance: Approx 1M ohm.
Bandwidth: 40 Hz ~ 400 Hz (sine wave)

DC voltage

Remarks:

Input impedance: Approx 1M ohm.

Resistance and Continuity check

Remarks:

Open voltage: Approx 0.9 V
Buzzer sounds : Less than 30 ohms