7
Instruction Manual for SABER MAGNET 24V
1-888-726-8869
www.sanuvox.com
MAINTENANCE
How to Replace Lamp(s)
Replacing lamp on the SABER MAGNET 24V is quick and easy. Simply turn off the power source, remove lamp from duct,
dispose of old lamp and replace with new Sanuvox branded UV lamp, replace lamp in duct and turn power source back on. See
below for detailed step by step instructions.
CAUTION:
In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.
Step by Step Lamp Replacement
1. First disconnect white socket from the old lamp. Then, loosen the 2
screws on the retainer ring and turn retainer ring counterclockwise .
Pull out the old lamp. Dispose of old lamp.
NOTE:
UV lamps can be disposed/recycled after use, as any other
fluorescent lamps. Contact and follow your local and national authorities’
specific instructions.
2.
Prepare the new lamp.
Remove the contents from packaging. Only
after you have visually inspected the UV lamp should you cut open the
packaging.
3. Carefully slide the new
UV lamp
out from the cardboard sleeve. Be sure
to wear the
cotton gloves
(included) guaranteeing a clean lamp free
from fingerprints. Fingerprints on the lamp will negatively impact the UV
output of the lamp.
STEP 1
STEP 2
STEP 3
4. Place the new lamp in the duct. Tighten the 2 screws on the retainer ring
and turn retainer ring right. Connect white socket from the new lamp.
Then, reset your product and its lamp timer (see page 8).
STEP 4
How to Clean your Product
For optimal performance, the lamp(s) should be kept free of dust and residue deposit: clean every two to three months with a
soft tissue and mild soap or alcohol based solution. Always spot test the cleaner to make sure it does not damage the surface.
CAUTION:
Under no circumstance should water be sprayed or splashed onto the product.
STORAGE
The SABER MAGNET 24V is an in-duct unit working continuously and automatically and therefore, requires no specific storage.