 S1000 VOC FOR SMOKING ROOM  

INSTALLER INSTRUCTIONS 

These instructions are for a smoking room of a maximum of 9600 cu ft 

Box contains:  

 

Une (1) S1000 VOC unit that includes:  

o

 

One (1) "J" lamp UVC/UVV with yellow tips (part LMPHGXJ160-8  

6" exposed

)  

o

 

One (1) "J" lamp all UV-V with blue tips (part LMPHXJ160)  

o

 

Two (2) Multi voltage ballasts (part BST120/277SHS) and two lamp-holding brackets. 

o

 

One (1) Relay (part MSCELC16) connected to the all UVV lamp  

o

 

Twenty (20) feet of wire that can be inserted in BX shield.  

o

 

One (1) VOC controller (part MSC1A) factory’s pre-set    

 

Four (4) replacement pre-filters (part MSCFTR2) 
 

 

 

LAMP INSTALLATION (this step can be done later) 

1.

 

Open the front door on the S1000 unit. 

2.

 

Open the door access to the aluminum box by removing the two 
wing nuts. (see picture aside) 

3.

 

Remove the BLUE END CAP (LMPHXJ160) lamp from packaging: 

Use the gloves provided

4.

 

Identify the ballast showing LMPHXJ160, follow the wire and insert 
it in the appropriate clamp, using the foam tape supplied.   

5.

 

Holding the cap with one hand, plug the white connector tightly 
on the lamp 

6.

 

Repeat the operation with the second lamp (LMPHGXJ160-8). 

7.

 

Put the cover back on with the 2 wingnuts. 

 

 

 

 

Controller 

Casing 

Wiring 20’ 

Relay 

Summary of Contents for S1000

Page 1: ... One 1 VOC controller part MSC1A factory s pre set Four 4 replacement pre filters part MSCFTR2 LAMP INSTALLATION this step can be done later 1 Open the front door on the S1000 unit 2 Open the door access to the aluminum box by removing the two wing nuts see picture aside 3 Remove the BLUE END CAP LMPHXJ160 lamp from packaging Use the gloves provided 4 Identify the ballast showing LMPHXJ160 follow ...

Page 2: ...it works IMPORTANT you may have to calibrate the VOC Monitor refer to the monitor instructions or call Sanuvox WORKING INSTRUCTION The VOC controller analyzes the air every 90 seconds A 20 foot power cord connects it via a relay to the device to activate the second oxidizing lamp on demand The S1000 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC ...

Page 3: ...nic board initializes itself 2 After 5 minutes the GREEN LED will turn solid Blow some cigarette smoke into the controller If the other RED LED lights up the relay triggers on the oxidizing lamp all UVV This sequence reproduce itself every minute or so When there is no more smoke VOC the RED LED is turned off at the same time as the lamp MAINTENANCE INSTRUCTIONS MONTHLY Change the pre filters that...

Page 4: ... it via a relay to the device to activate the second oxidizing lamp on demand The S1000 VOC unit runs continuously so its regular lamp purifies the air constantly This dual zone lamp UVC UVV is enough when there are only one or two smokers However if there is much smoke in the room the VOC controller that samples the air on a regular basis will then trigger the second all UVV lamp for a period of ...

Reviews: