background image

Sanuvox Technologies Inc, © 2019 All rights reserved. November 2021 EN v.5

Instruction Manual

Photos illustrating products are non contractual.

SABER MAGNET 24V

UV COIL CLEANER

Residential Model

Installation Date:  _______________   Installed by:  _________________
Installer Contact Info.:  _________________________________________

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit 

or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.

 NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP. 

1. 

Installation and servicing of UV units or systems  (in an 

air conditioning system or not) can be hazardousOnly 

trained and qualified service personnel

 should install, 

repair or service equipment.

2.  Untrained personnel can perform basic maintenance 

functions  such  as  replacing  lamp(s)  and/or  filter(s).  All 

other operations should be performed by trained service 

personnel.

3.  The unit is not to be used by persons (including children) 

with reduced physical, sensory or mental capabilities, or 

lack of experience and knowledge.

 

 CAUTION: Unit is not a toy. Keep away from 

unsupervised children. Do not leave children unattended 

with the unit.

4.  DO NOT hang onto the UV unit or system

5.  Some UV units or systems could be heavy: Make sure 

you have a minimum of 2 people to safely move or install 

these UV units or systems, and make sure you adopt the 

most ergonomic position possible (use UV unit or system 

handles, if applicable).

 

 CAUTION:  Installing or maintaining heavy equipment, 

especially overhead, can cause back pain or other injuries. 

6.  When installing or servicing an overhead UV unit or system, 

be careful not to fall off the stepladder. Furthermore, make 

sure the UV unit or system latches are always in place to 

prevent falling parts.

 

 CAUTION: Some parts of some UV units and systems 

may open suddenly if the UV unit or system is installed 

high up without its locks.

7.  Units that are obviously damaged must not be operated.

8. 

 CAUTION: When working on the UV unit or system, 

observe precautions on the literature, tags and labels 

attached to the UV unit or system, and all other safety 

precautions considered as best practices in the HVAC 

industry, if applicable.

9.  When applicable, local regulation may comprise more 

restrictive  installation  and/or  certification  requirements. 

The aforementioned requirements prevail on those of this 

document and the installer agree to conform to these at his 

own expense.

10.  Follow all the safety instructions outlined in this document 

and respect all local and national codes applicable.

11.  All UV units or systems contain a UV-C source. Damage to 

the housing or unintended use of the UV unit or system may 

result in harmful UV-C leaks. UV-C may, even in little doses, 

cause harm to the eyes and skin.

12.  Never expose eyes or skin to an operating UV lamp. 

Therefore, before installing or performing maintenance 

on the UV unit or system, TURN OFF AND DISCONNECT 

the UV unit or system from all power sources (there 

may be more than one switch to disconnect) and also 

disconnect the HVAC system, is applicable.

 

 CAUTION: Electrical shock may cause injuries or 

possibly  death.  FIRST  AID  INSTRUCTIONS:  If  injured, 

consult a doctor.

13.  UV rays may damage certain types of filters (polymer or 

plastic); please keep the UV unit or system light away from 

shining directly on plastic.

14.  When installing or performing maintenance on the UV unit 

or system, it is recommended to wear safety gloves. In 

order to avoid reduced performance of lamp(s), do not 

touch lamp glass without gloves.

15.  Just like conventional fluorescent lamps, UV lamps contain 

a small quantity of mercury: if a lamp breaks, clean and 

dispose of with care. UV lamps can be disposed/recycled 

after use in the same way as any other fluorescent lamps. 

Contact and follow the specific instructions of your local 

and national authorities.

16. 

Use  only  specified  SANUVOX  branded  replacement 

UV lamps for your UV unit or system. Use of any other 

lamps will void your warranty and can result in damage to 

the UV unit or system.

17.  Sanuvox UV units or systems are not waterproof. DO NOT 

INSTALL OUTDOORS OR IN WET LOCATION unless 

specified otherwise.

18.  The use of a UV unit or system is a supplement to and 

not a substitute for standard infection control practices; 

users must continue to follow all current infection control 

practices, including those related to the cleaning and 

disinfection of environmental surfaces.

SAVE THESE INSTRUCTIONS

For any inquiries on a UV unit or system, contact :

Robert Smith 

146 Barr St, Saint-Laurent

Quebec, CA, H4T 1Y4 

1-888-726-8869 

[email protected]

Summary of Contents for BST24G48ET

Page 1: ...he UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safety instructions out...

Page 2: ...lation 4 OPERATION 6 How to Operate your Product 6 How to Read the Ballast Display 6 How to Reset your Product and its Lamp Timer 6 Step by Step Product and Lamp Timer Reset 6 MAINTENANCE 7 How to Replace Lamp s 7 Step by Step Lamp Replacement 7 How to Clean your Product 7 STORAGE 7 ULTRAVIOLETS UVC 8 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 8 TROUBLESHOOTING 8 What you will need 8 S...

Page 3: ...nd a loss in energy efficiency as the equipment must work harder to provide the same air temperature Installed on the air conditioning s evaporator coil the SABER MAGNET 24V keeps the system running at top efficiency saving you electricity and preventing the coil from becoming a source of bad air quality and bad odor A 16 UVC Lamp B Main Bracket C Magnetic Multi Bracket D Lamp Retaining Ring E Bal...

Page 4: ...69 What s included The ballast 1 UV lamp and a basic installation kit The installation kit includes a UV caution decal a maintenance decal a pair of cotton gloves 2 hex head screws 2 self tapping short Phillips screws 2 short Phillips screws one long Phillips screw a nut a plastic view port a main bracket a retainer ring a magnetic multi bracket and a round magnet Step by Step Setup Installation 1...

Page 5: ...esigned so that it can only be installed one way You may have to rotate the socket 90 to line up the pins with the holes CAUTION Power supply cable should not be coiled STEP 3 STEP 4 STEP 5 STEP 6 5 Drill a 0 25 hole on the outside of the plenum and install the view port When the lamp is ON the glow of the lamp will be visible through this port 6 Connect the two black wires to the 24VAC terminals ...

Page 6: ...led When the LED flashes it is time to replace the UV Lamp after 1 year of use Once the UV Lamp has been replaced hold the RESET button for 3 seconds to reset the ballast timer Normal Operation SOLID RED In operation system OK FLASHING RED once every second Lamp 8 700 h time to replace the lamp FLASHING RED twice every second Lamp failure FLASHING RED three times every second Ballast failure FLASH...

Page 7: ...amp Remove the contents from packaging Only after you have visually inspected the UV lamp should you cut open the packaging 3 Carefully slide the new UV lamp out from the cardboard sleeve Be sure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints Fingerprints on the lamp will negatively impact the UV output of the lamp STEP 1 STEP 2 STEP 3 4 Place the new lamp in t...

Page 8: ... to operate the equipment NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT TROUBLESHOOTING If your product ...

Page 9: ...ement lamp and reset lamp timer See Product and Lamp Timer Reset instructions on page 6 Error Code 3 EC3 Ballast has failed Press the reset button once to attempt to restart the ballast Shut the power to the ballast hard reset wait 10 seconds and turn the power back ON Check power source to confirm that it is within specifications on product label Get a replacement ballast Error Code 4 EC4 Voltage...

Page 10: ... At its option SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects C...

Reviews: