6904-002027 <02>
6
2 Mount the Wall Plate
Solid concrete or concrete block
2-1 Mark the wall
2-2 Drill pilot holes
10 mm
(3/8 in.)
CAUTION:
Avoid potential injuries or property damage!
Ù
Pilot
holes
MUST
be
drilled
to
a
depth
of 63.5
mm
(2½
in.)
using
a 10
mm
(3/8
in.)
diameter
drill
bit.
Ù
Never
drill
into
the
mortar
between
blocks.
IMPORTANT:
For stacking confi gurations, stack from the top
down.
Level the wall plate
[01]
and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage!
Ù
Mount the wall plate
[01]
directly onto the concrete
surface.
Ù
Minimum solid concrete thickness: 203mm (8 in.).
Ù
Minimum concrete block size: 203 x 203 x 406 mm (8 x
8
x
16 in.).
[01]
63.5 mm
(2
½
in.)
11 mm
(7/16 in.)
2-3 Insert anchors and screws
[07]
[11]
[01]
Insert anchors
[11]
/
[07]
.
Use the lag bolt
[04],
washer
[06]
, and anchor
[11]
to secure the top of the wall
plate. Use the #8 screw
[05]
and anchor
[07]
to secure the bottom of the wall
plate.
CAUTION:
Improper
use
could
reduce
the
holding
power
of
the
lag
bolt.
To
avoid
potential
injuries
or
property
damage:
Ù
Be
sure
the
anchors
[11]
/
[07]
are seated
fl ush
with
the
concrete
surface.
Ù
Tighten
the
lag bolt
[04]
only
until
the washer
[06]
is
pulled
fi rmly
against
the
wall
plate
[01]
.
Ù
DO NOT
over-tighten the lag bolt
[04]
or screw
[05]
.
[04]
[05]
[06]