3.1 LOCATION
3.1.1  

Inlet must always be on the right.

3.1.2  

The outlet of this water heater acts as a vent and must not be blocked or    

 

restricted in any way.

3.1.3  

Only use Santon open outlet spouts.

3.1.4  

The installation must be carried out in accordance with the relevant requirements  

 

of:  

 

• The appropriate Building Regulations either The Building  Regulations, 

 

• The Building Regulations (Scotland) or Building Regulations (Northern Ireland). 

 

• The Water Fittings Regulations or Water Byelaws in Scotland. THE WATER  

 HEATER
3.1.5  

Select a suitable site but check that:

 

a) There is enough clearance under the heater to allow removal of the element  

 

plate (210mm).

     

b) When using the outlet spout, it will swing over the sink (or sinks) to be sup- 

 plied.
     

c) There are no hidden services where the wall is to be drilled.

3.1.6  

Mark the position of the fixing holes (as shown in FIGURE 01).

3.1.7  

Drill and plug the hole positions.

3.1.8  

Screw in the top two screws leaving heads 3mm from the wall.

3.1.9  

Hang the heater on the two top screws.

3.1.10   Screw in bottom screw to secure heater. 3. PLUMBING REQUIREMENTS
3.1.11   The water heater is designed to be connected directly to the mains via the valve  
 

provided. It is recommended that a WRAS listed isolating valve (not supplied) be  

 

fitted in the water supply pipe to the heater to allow for servicing.

3.1.12   To remove the terminal cover  use a large flat bladed screwdriver to relieve the  
 

snaps located towards the front of the terminal cover at either side. Gripping the  

 

cover at the front, pull downwards.

3.1.13   To fit the cover, locate the hinge at the back. Slide the snaps into place. Apply  
 

pressure to the front of the cover pushing it backwards and upwards until it snaps  

 

securely in place.

3.2  

PLUMBING

3.2.1  

Connect the control valve supplied to the inlet pipe on the water heater.

3.2.2  

Connect the cold water main to the control valve using 15mm outside diameter  

 

pipe (either copper to BS EN 1057 or stainless steel to BS 4127).

3.2.3  

Push the outlet spout directly into the outlet fitting.

3.2.4  

TO REMOVE OUTLET SPOUT

 

a) Remove terminal cover.

 

b) Push white ring upwards towards body of fitting.

 

c) Pull spout downwards.

3.3  

ELECTRICAL

3.3.1  

Warning: this appliance must be earthed. It is suitable for a.c. supply only. Electri 

 

cal installation must be carried out by a competent electrician and be in accord 

 

ance with the latest I.E.E. regulations.

3.3.2  

Nominal cross-section of supply cable must be at least 1.5mm2. A double pole  

 

isolating switch with a contact separation of at least 3mm in each pole must be  

 

incorporated in the supply.  

 3

.0 INSTALLATION

Summary of Contents for Aquarius A7/3

Page 1: ...and understand these instructions before starting work Please leave this leaflet with the user following installation PACK CONTENTS Heater Fixing screws and plugs Spout Valve Installation and User Instructions and Guarantee card WARNING This water heater must only be installed by competent persons 36005792 issue 06 ...

Page 2: ... This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concern ing use of the appliance in a safe way and understand the hazards involved Children shall not play with the appli ance Cleaning and user maintenance shall not be made by ch...

Page 3: ...e XXS XXS XXS XXS Energy Efficiency Class C C C C Energy Efficiency 31 4 31 4 31 9 31 9 Annual electricity consumption kWh 587 587 578 578 Daily fuel consumption kWh 2 850 2 850 2 790 2 790 Thermostat setting 60 C Specific precautions that shall be taken when the water heater is assembled installed or maintained and disposed of at end of life See Section 2 to 6 Table Technical parameters in accord...

Page 4: ... recommended that a WRAS listed isolating valve not supplied be fitted in the water supply pipe to the heater to allow for servicing 3 1 12 To remove the terminal cover use a large flat bladed screwdriver to relieve the snaps located towards the front of the terminal cover at either side Gripping the cover at the front pull downwards 3 1 13 To fit the cover locate the hinge at the back Slide the s...

Page 5: ...s are made see Figure 02 3 3 5 Loosen the top screws securing the cable grip 3 3 6 Pass the cable underneath the cable grip and through the top moulding 3 3 7 Make the connections to the terminal block as follows Live brown or red wire to terminal marked L Neutral blue or black wire to terminal marked N Earth green or green yellow wire to terminal marked 3 3 8 Secure the cable in the cable grip by...

Page 6: ...ATER UNTIL IT IS FILLED WITH WATER 4 1 Fill with water by opening tap and leaving open until a full bore of water flows from the outlet 4 2 Switch on water heater at double pole isolating switch The heater will heat water to the temperature set on the thermostat 4 3 Check water is heating correctly 7 litre 1 2kW after 10 mins water temperature will increase by 20 C 7 litre 3kW after 10 mins water ...

Page 7: ...ontrols and safety valves have been fitted correctly Any valves and controls are of the Santon recommended type and specification The unit has not been modified or tampered with in any way and has been regularly main tained as detailed in the Installation and User Instructions The unit has been used only for heating potable water The unit is not guaranteed against damage by frost and the inner con...

Page 8: ...agon Business Centre Springfield Road Hayes Middlesex UB4 0TY Tel 020 8606 3567 Parts Center Tel 0344 292 7057 www partscenter co uk Newey Eyre Unit 3 5 Wassage Way Hampton Lovett Ind Estate Droitwich Worcestershire WR9 0NX Tel 01905 791500 Fax 01905 791501 UK Spares Ltd Unit 1155 Aztec West Almondsbury Bristol BS32 4TF Tel 01454 620500 Alternatively contact your local supplying merchant wholesale...