Aqualine
Technical Specification
Specification
Element
Alloy sheathed element, incorporated into an easily removable heater
plate, should replacement be necessary.
Inner Container
Heavy gauge copper suitable for a maximum working pressure of
6 bar (pressure tested to 15 bar). A minimum supply pressure of
1 bar recommended.
Outer Casing
The main body is substantial gauge sheet steel, anti-corrosion treated,
and finished in white stoved enamel. End covers are moulded in grey
ABS. The back has three fixing points for wall mounting.
Insulation
Approved CFC/HCFC-free (ODP zero) polyurethane foam.
GWP 2.72 (Global Warming Potential).
Safety Feature
IPX4 rated.
TMV2 Thermostatic Blending Valve
Precise control of outlet temperature (range 35°C to 60°C)
and lockable control knob. Temperature stability ±2°C.
Expansion/Pressure Kits
If the inlet water pressure is in excess of 4.1 bar, it is essential that
the Santon unvented kit ALK01 is also installed with the heater.
This kit comprises expansion vessel, expansion relief valve,
non-return valve and pressure reducer/strainer.
In instances where the water pressure is below 4.1 bar, but expansion
cannot occur back down the mains, kit ALK02 must be used
(comprises expansion vessel, expansion relief valve and
non-return valve).
Pressure and Temperature Relief Valve
This is factory-fitted to the unit, accessible beneath the removable
access cover and is set at 7 bar / 90°C.
Thermostat
Rod type, adjustable 10°C to 70°C with integral manually-resettable
over-temperature cut-out.
Installation
Plumbing Connections
Inlet and outlet are 15mm copper tails. The factory-fitted temperature
and pressure relief valve discharge pipe must be connected to waste
(drain) via the tundish supplied. The drain pipe from the tundish
must fall continuously and be 22mm diameter copper pipe. It must
discharge in a visible and safe place. The pipe must not be reduced
in bore or blocked under any circumstances and should be protected
from frost.
Electrical
This unit is supplied with 1 metre of 3-core cable fitted.
The installation must comply with BS 7671 ‘Requirements for
electrical installations’ (IEE Wiring Regulations). It must be fully
earthed and permanently connected to the electrical supply through
a double pole linked isolating switch with minimum breaking capacity
suitable for the loading.
Approvals
3kw models – Kiwa and Nemko approved.
CE marked.
4.5kW models – Kiwa approved. CE marked.
Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004,
BS OHSAS 18001:2007 and ISO 50001:2011 registered factory.
Warranty
Two years product warranty, from date of purchase, with on-site
service support. Full details are contained in the Installation
Instructions supplied with each unit.
Ordering Guide
Model
ErP rating
Product Code Litres
Rating
AL07/3
C
94 050 012
7
3.0kW @ 240V
(2.75kW @ 230V)
single phase AC
AL10/3
D
94 050 013
10
3.0kW @ 240V
(2.75kW @ 230V)
single phase AC
AL15/3
C
94 050 014
15
3.0kW @ 240V
(2.75kW @ 230V)
single phase AC
AL15/4.5
C
94 050 015
15
4.5kW @ 240V
(4.1kW @ 230V)
single phase AC
Dimensions
Model
A
(mm)
B
(mm)
C
(mm)
Weight
(kg)
Empty
Full
AL07/3
456
240
240
6.5
13.5
AL10/3
542
240
240
7.5
17.5
AL15/3
517
330
330
11.6
26.6
AL15/4.5
517
330
330
11.6
26.6