User manual SNC-565IR/W
_________________________________________________________________________________
- 15 -
INDOOR
: For indoor applications of colour temperatures of 3000°K to 10500°K.
AWC (Auto White Balance Control):
Automatic white balance if you hold a white sheet of paper infront of the camera and
press SET (sufficient light conditions required).
Manual: The red and blue values can manually be set. Select „MANUAL“ and press SET.
Increase or decrease the red values („R-GAIN“) and blue values („B-GAIN“). Once you
are satisfied with your choice, press SET.
NOTE:
It may happen that the white balance isn’t done properly under the following conditions:
if the surrounding mainly contains objects of high colour temperature, e.g. blue sky or
sundown
under dull, damped light conditions
if the camera is pointed directly to a fluorescence light or if the camera is located in a
surrounding with changing light conditions
2.5. Backlight
If the object is exposed to strong back light, the function „BACKLIGHT“ enables to achieve a
clear and sharp picture of both the object and the background.
1. Press SET to call up the main menu. Use the up/down buttons to select „BACKLIGHT“.
2. Select the setting by using the left/right buttons.
HIGH / MIDDLE / LOW:
Adjustment of sensitivity.
OFF:
Backlight
compensation
is
switched
off.
„BACKLIGHT“ is ON.
„BACKLIGHT“ is OFF.