TRIM INSTALLATION

- Place the shower plate on the all thread.

- Screw the handle flange onto the handle bell.

- Screw the handle bell with handle Flange and washer onto the all

   thread. Press them firmly against the plate  and mark the position. 

  Cut off the excess thread.

- Insert the Handle onto the stem. Measure the excess between 

  the handle bell and the handle.  Take off the handle and cut the

  excess stem.

- Reinsert the handle onto the stem. Using the Allen Key provided,

  tighten the handle set screw firmly. 

Screw the Diverter Knob onto the Diverter Rod. 

- Place the Trim Plate Grommet onto the designated hole for the

  Diverter Rod on the Trim Plate.

INSTALLATION INSTRUCTIONS

All Thread

Lock Nut

Lock Plate

S

T

Diverter Rod

Trim Plate

Diverter Knob

Trim Plate Grommet

Stem

S

T

PM-280 - SERVICE VALVE (OPTIONAL)

VALVE CARTRIDGE -  TE010

MECHANICAL STOP- TE013

LIMIT STOP- TE014

PM-010 - STEM

TEFLON WASHER

PM-009 - LOCK PLATE

PM-012 - LOCK NUT

PM-011 - ALL THREAD

FILTER SCREEN - TE012

DIVERTER CARTRIDGE- TE050

PM-460 - DIVERTER SLEEVE  

DIVERTER KNOB-P0258

PLATE GROMMET- PM-465

PAGE 03

ILLUSTRATION C

COLD

WARM

WARMER

HOT

FLANGE WASHER HANDLE FLANGE HANDLE BELL HANDLE

FLANGE ADAPTER

PLATE

Reviews: