6 Maintenance

NOTE: Do not operate the unit without the proper filter or with a less
effective filter. The heat exchange coils inside the unit could become
clogged, resulting in a loss of effectiveness and/or efficiency and may
require disassembly to clean.

6.1 Air Filter

The Santa Fe Advance ships with a 1" pleated fabric filter and a ¼"
aluminum framed pre-filter installed. Operating the unit with a dirty or
obstructed filter will reduce dehumidifier capacity and efficiency and may
cause the compressor to cycle on and off unnecessarily. 

6.2 Cleaning & Replacement

Check filters every six months. Clean and/or replace when filters are visibly
dirty. See cleaning instructions below. Replacement filters can be ordered
from Therma-Stor by calling 1-800-533-7533.

The ¼" washable pre-filter should not to be discarded. Inspect the pre-filter
for debris, dirt, or other obstructions at the same time the 1" pleated fabric
filter is checked. Wash the ¼" pre-filter every time the 1" pleated fabric filter
is replaced. To clean the ¼" pre-filter, remove filter from the unit, rinse the
¼" pre-filter in water with the water flowing through the aluminum support
mesh side. Refer to Figure 11. Allow the filter to dry completely before rein-
stalling. Reinstall the filters per the instructions below or on the tag located
on the ¼" pre-filter.

IMPORTANT

Figure 11:

Pre-filter rinsed in water, mesh side up.

Summary of Contents for 4025699

Page 1: ...humidifier Owner s Manual READ AND SAVE THESE INSTRUCTIONS Includes Safety Operating Instructions and Warranty Information Santa Fe Advance P N 4025699 2005 Therma Stor LLC Manual P N 4025565 Sales Inquiries 800 934 9194 ...

Page 2: ...n 6 4 1 Location 6 4 2 Electrical Requirements 6 4 3 Condensate Water Removal 7 5 Operation 7 5 1 Humidity Control Adjustment 7 5 2 Defrost Cycle 8 5 3 Blower Fan Switch 8 6 Maintenance 9 6 1 Air Filter 9 6 2 Cleaning and Replacement 9 6 3 Removing Filters 10 6 4 Installing Filters 10 7 Service 10 7 1 Technical Description 10 7 2 Troubleshooting 11 8 Accessory Replacement Parts 12 Warranty 13 ...

Page 3: ...t Never operate electrical equip ment near or in standing water Do not stick your fingers or other objects through the safety grills Do not restrict airflow into or out of the unit This may cause the unit to overheat Unit should never be serviced or cleaned while it is plugged in Do not sit or stand on the unit or use as a shelf or table Before leaving the Santa Fe Advance unattended ensure childr...

Page 4: ...formance In order to efficiently control the humidity levels the area in which the dehumidifier is to be placed must be free of water intrusion or excessive fresh outside air infiltration Before installing the Santa Fe Advance water intrusion and air infiltration problems should be addressed 2 Registrations The Santa Fe Advance conforms to UL STD 474 and CSA Standard C22 2 No 92 2 Specifications M...

Page 5: ...arefully bring unit to upright position 6 Wait 10 minutes before operating Note Operating the unit immediately after bringing it to an upright position can possibly damage the compressor A short amount of time is needed to allow the oil to return to it s reservoir for lubrication 3 2 Drain Hose Take drain hose off of drain port With scissors cut one inch off of hose end to eliminate dented area Pl...

Page 6: ...ator has been included near the intake of the unit To ensure the unit will drain properly the unit should be positioned so the level bubble appears in the non shaded area of the level indicator as shown Refer to Figure 6 If the unit is placed on an unlevel surface place shims underneath the unit until bubble in the level dial is in the correct position Failure to level the unit may result in leaka...

Page 7: ... 12 20 away from the unit Check hose regularly to ensure it is clear and water is draining properly If floor drain is not easily accessible a condensate pump kit with a 20 hose is available Refer to page 12 for ordering accessories 5 Operation 5 1 Humidity Control Adjustment The humidity control is an adjustable switch that turns the dehumidifier on and off It turns on when the relative humidity o...

Page 8: ...f room temperature To turn the unit off position the humidity dial to the far left and set fan control to auto 5 2 Defrost Cycle An automatic defrost thermostat is attached to the refrigerant tubes inside the unit It will automatically shut the compressor off if excessive frost forms on the evaporator coil The blower will continue to run causing air to flow through the evaporator coil and melt the...

Page 9: ...eck filters every six months Clean and or replace when filters are visibly dirty See cleaning instructions below Replacement filters can be ordered from Therma Stor by calling 1 800 533 7533 The washable pre filter should not to be discarded Inspect the pre filter for debris dirt or other obstructions at the same time the 1 pleated fabric filter is checked Wash the pre filter every time the 1 plea...

Page 10: ...vicing the Santa Fe Advance with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qualified service people should service this unit 7 1 Technical Description The Santa Fe Advance uses a refrigeration system similar to an air conditioner s to remove heat and moisture from incoming a...

Page 11: ...erature gas to repeat the process 7 2 Troubleshooting No dehumidification neither blower nor compressor run with fan switch AUTO 1 Unit unplugged or no power to outlet circuit breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defective No dehumidification compressor does not run but blower runs with fan switch AUTO and humidity cont...

Page 12: ...peller rotation 3 Defective blower 4 Defective blower switch Evaporator coil frosted continuously low dehumidifying capacity 1 Dirty air filter or air flow restricted 2 Defrost thermostat loose or defective 3 Low refrigerant charge If none of the above has fixed the issue call the service department at 1 800 533 7533 8 Accessory Replacement Parts 4025568 Pleated Air Filter 88 x 11 75 x 11 75 40258...

Page 13: ...days after said two 2 year period to Therma Stor LLC Madison WI together with proof of purchase of the dehumidifier THIRD THROUGH FIFTH YEAR WARRANTY Therma Stor LLC further warrants that for a period of five 5 years the condenser evaporator and compressor of the Santa Fe Advance dehumidifier will operate free of any defects in material or workmanship or Therma Stor LLC at its option will repair o...

Page 14: ... the period of time if any that the Santa Fe Advance Dehumidifier is out of service while awaiting covered warranty service UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE SANTA FE ADVANCE HUMIDIFIER OR ANY PART THEREOF ALL OTHER WAR RANTIES IMPLIED BY LAW INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL ALSO EXPIRE ALL WARRANTIES MADE BY THERMA STOR LLC ARE SET F...

Page 15: ...transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2005 Therma Stor LLC All rights reserved PO Box 8050 2001 S Stoughton Road Madison WI 53708 Phone 608 222 5301 Fax 608 222 1447 Web www thermastor com Email sales thermastor com Sales Inquiries 800 934 9194 ...

Reviews: