47
4.6
PARAMETER SELECTION
The Table below provides information of the parameters that are available for
modification using the front panel display. The table also provides information on the ranges
available for each parameter as well as to which weld process the parameter is available.
*1 : The values listed in the “Default” column are the “Factory Default Settings”. Once these are
changed, the last setting(s) before the unit is turned off will remain in memory for the next turn
on. These NEW settings will become the new default setting. The user must manually adjust
the setting to the values in the above chart to return to the “Factory Default Settings”.
*2 : Pulse frequency units are dependent on frequency setting range as shown below:
Setting range
Units
0.5 to 20 Hz
0.1Hz
20 to 100Hz
1Hz
100 to 500Hz
5Hz
TABLE 4-3 : Front Panel Parameter Selection Ranges.
Process
PARAMETER
RANGE
Default *1 Units
STK LFT HF
200AP
AC Frequency
15 to 150Hz
60Hz
1Hz
YES YES YES
Wave Balance
10 to 65%
20%
1%
YES YES YES
Weld Current (STICK) 5 to 160A
80A
1A
YES YES YES
Weld Current (TIG)
5 to 200A
80A
1A
YES YES YES
Pulse Base Current
5 to 200A
80A
1A
NO YES YES
Pulse Peak Current
5 to 200A
120A
1A
NO YES YES
Hot Current
0 to 70A
20A
1A
YES NO YES
Initial Current
5 to 200A
30A
1A
NO YES YES
Crater Current
5 to 200A
30A
1A
NO YES YES
Pulse Duty
15 to 80 %
50%
1%
NO YES YES
Pulse Frequency
0.5 to 500.0 Hz
100.0Hz
*2
NO YES YES
Pre-Flow Time
0.0 to 1.0 sec
0sec
0.1sec
NO YES
YES
Post-Flow time
0.0 to 60 sec
10sec
0.1sec
NO YES
YES
Spot Time
0.5 to 5.0 sec
2sec
0.1sec
NO NO
YES
Up-Slope Time
0 to 15 sec
1sec
1sec
NO YES
YES
Down-Slope Time
0 to 25 sec
3sec
1sec
NO YES
YES
Summary of Contents for SANARG 200AP
Page 2: ......
Page 4: ......
Page 8: ......
Page 24: ...24 PAGE LEFT INTENTIONALLY BLANK ...
Page 35: ...35 Figure 3 2 Electrical Input Connections 200AP ...
Page 60: ...60 PAGE LEFT INTENTIONALLY BLANK ...
Page 66: ...66 PAGE LEFT INTENTIONALLY BLANK ...
Page 79: ...79 PAGE LEFT INTENTIONALLY BLANK ...
Page 80: ...80 10 1 INTERCONNECT DIAGRAM 200AP ...
Page 81: ...81 ...
Page 82: ...82 10 2 EXPLODED VIEW 200AP ...
Page 83: ...83 ...
Page 84: ...84 PAGE LEFT INTENTIONALLY BLANK ...
Page 89: ...PAGE LEFT INTENTIONALLY BLANK ...