37
3.6.2 GENERAL
Model
ID-1600TP-U1E
General
Approval/Standard
IEC60974-1,IP23S
Language
English
Front Panel
Front Panel Pot
Welding Current / Parameters Adjustment
Push to voltage display
Function Select Button
Process
STICK / HF TIG / LIFT TIG
Mode
See TABLE 1
OUTPUT
STD / SLOPE / REPEAT / SPOT
Pulse
ON
Parameter Select
Button
Forward
/ Back
See TABLE 2
Current
Weld / Hot / Initial / Crater
Pulse Peak / Pulse Base
Pulse
Duty / Frequency
Time
Sequence
Pre Flow/ Post Flow / Spot
Up Slope / Down Slope
Save / Load Button
Save / Load
Ch1 – Ch5
Digital Panel Meter
Indicator
Amperage / Parameter / Error Code ( See TABLE 3 )
* Holds weld value for 8sec after weld current has stopped
Value stops displaying if control knob is rotated
LED Indicator
Selected Function and Parameter
RED
HOT START, INITIAL CUR, PEAK(WELD) CUR,
BASE,
CRATER CUR, A
PULSE WIDTH, %, PULSE FREQ, Hz
PULSE ON, STD, SLOPE, REPEAT, SPOT,
STICK, HF TIG, LIFT TIG
PRE-FLOW, UP SLOPE, SPOT TIME, DOWN SLOPE,
POST FLOW, sec
GREEN
VRD ON
* Both VRD light off in HF TIG & LIFT TIG modes
Shielding Gas Output
5/8 18inch UNF (F)
Cooling Water Output
None
Output
DIN style
Remote Control
8 pin connector for Torch Control
Rear Panel
ON/OFF Switch
Switch
Shielding Gas Input
5/8 18inch UNF (F)
Cooling Water Input
None
Size
Width
Height
Depth
130 mm
260 mm
320 mm
Weight (Shipping)
8kg
Material of Outline Case
Plastic
Attachment
Terminal plug 2 pcs
Operation Manual 1 pcs
Summary of Contents for SANARG 160P
Page 2: ......
Page 4: ......
Page 8: ......
Page 15: ...15 1 3 2 GRAPHIC SYMBOL LEGEND ...
Page 24: ...24 PAGE LEFT INTENTIONALLY BLANK ...
Page 35: ...35 Figure 3 1 Electrical Input Connections 160P ...
Page 47: ...47 PAGE LEFT INTENTIONALLY BLANK ...
Page 64: ...64 PAGE LEFT INTENTIONALL BLA ...
Page 76: ...76 10 1 INTERCONNECT DIAGRAM 160P ...
Page 77: ...77 ...
Page 78: ...78 10 2 EXPLODED VIEW COMPONENT LAYOUT 160P ...
Page 79: ...79 ...
Page 80: ...80 PAGE LEFT INTENTIONALL BLANK ...