6.06 Slope Function
6.06.01 2T Slope Function
(Set with internal parameter P19, Factory setting is P19 OFF)
This is the function to control the slope operation under 2T mode. It is necessary to set the upslope
time, down slope time, initial current and crater current. The current wave becomes as shown below
when this function is valid and invalid (OFF).
<2T Slope Function OFF> <2T Slope Function ON>
Internal parameter P19 to OFF
.
Internal parameter P19 to ON.
6.06.02 4TS Mode Setting
(Set with internal parameter P20, Factory setting is P20 OFF)
In the 4TS mode setting, when a torch switch is turned off during downslope, choose whether or not
to weld exiting from down slope to the crater current.
<4TS mode setting is OFF (P20 to OFF)> <4TS mode setting is ON (P20 to ON)>
ON
Contactor
Output
current
Iw
Hot cur.
Hot start
Output
current
Initial cur.
Up slope time
Down slope time
Iw
Iw
Crater cur.
Hot cur.
ON
Contactor
Welding end at the same time
t
h
switch OFF.
Welding exit from down slope to
the crater current.
Hot start
ON
ON
Contactor
HF
Output
current
Initial cur.
Up slope time
Iw
Iw
Crater cur.
solenoid
Hot cur.
Hot start
ON
ON
Contactor
HF
Output
urrent
Initial cur.
Up slope time
Down slope time
Iw
Iw
Crater cur.
solenoid
Hot cur.
Summary of Contents for IA-3000TP-U3E
Page 2: ......
Page 4: ......
Page 8: ......
Page 26: ...26 PAGE LEFT INTENTIONALLY BLANK ...
Page 32: ...32 PAGE LEFT INTENTIONALLY BLANK ...
Page 54: ...54 PAGE LEFT INTENTIONALLY BLANK ...
Page 74: ...74 PAGE LEFT INTENTIONALLY BLANK ...
Page 87: ...87 PAGE LEFT INTENTIONALLY BLANK ...
Page 94: ...PAGE LEFT INTENTIONALLY BLANK ...
Page 97: ...PAGE LEFT INTENTIONALLY BLANK ...