6.02 AC or DC HF TIG Welding
•
Connect work lead to positive terminal.
•
Connect TIG torch to negative terminal.
•
Switch machine on.
•
Wait for machine to cycle thru the start-up sequence during which the software version,
followed by the machine code is displayed on the front Panels Digital Display.
•
Set
DC or AC
or
AC-SOFT
weld current. If
AC
is selected, then set
AC FREQ
&
WAVE
BALANCE
&
VR CUR.
•
Connect remote control device. A remote control device is required for use during LIFT
TIG and HF TIG operation. See section 4.03, “14-PIN Remote Control Receptacle”, for
complete details of the remote device.
•
Enable the
WATER COOLING
function of the welding power source when utilizing water
cooled TIG torches
Use the Scroll Buttons to move to the parameter to be set. An illuminated LED indicates which
function is being adjusted on the weld sequence graph. Use the control knob to adjust each
parameter.
•
Set
PRE-FLOW
time.
•
Set
HOT START
current.
•
Set
POST-FLOW
time.
•
Set (WELD)
PEAK CUR
current.
•
Set
POST-FLOW
time.
Slope Mode Parameters if required.
•
Set
INTIAL CUR
current.
•
Set
UP SLOPE
time.
•
Set (WELD)
PEAK CUR
current.
•
Set
BASE
current.
•
Set
DOWN SLOPE
time.
•
Set
CRATER CUR
current.
Pulse Mode parameters if required.
•
Set
PULSE WIDTH
% for
PEAK CURRENT.
•
Set PEAK CURRENT.
•
Set
PULSE FREQ.
Commence welding.
Summary of Contents for IA-3000TP-U3E
Page 2: ......
Page 4: ......
Page 8: ......
Page 26: ...26 PAGE LEFT INTENTIONALLY BLANK ...
Page 32: ...32 PAGE LEFT INTENTIONALLY BLANK ...
Page 54: ...54 PAGE LEFT INTENTIONALLY BLANK ...
Page 74: ...74 PAGE LEFT INTENTIONALLY BLANK ...
Page 87: ...87 PAGE LEFT INTENTIONALLY BLANK ...
Page 94: ...PAGE LEFT INTENTIONALLY BLANK ...
Page 97: ...PAGE LEFT INTENTIONALLY BLANK ...